Powered by GoogleTranslate

Inspection Detail

Inspection: 112088489 - Ist

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 112088489
Report ID: 0950635
Date Opened: 11/06/1991

Site Address:
Ist
3700 W 190th St
Torrance, CA 90509

Mailing Address:
1070 E 233rd St, Carson, CA 90745

Union Status: NonUnion

SIC:1629

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/24/1992

Emphasis:

Case Closed: 04/11/1994


Related Activity
Type Activity Nr Safety Health
Accident 361325277
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $555 $0 $0 $0 $0 $555
Current Penalty $555 $0 $0 $0 $0 $555
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5144 D02 04/24/1992 05/24/1992 $0 $0 $0 -  
2. 01002 Other 5144 F01 04/24/1992 05/24/1992 $0 $0 $0 -  
3. 01003 Other 5194 H02E 04/24/1992 05/24/1992 $0 $0 $0 -  
4. 01004 Other 5162 A 04/24/1992 05/24/1992 $0 $0 $0 -  
5. 02001 Serious 6815 A 04/24/1992 05/06/1992 $555 $555 $0 -  

Investigation Summary

Investigation Nr: 170187918
Event: 11/03/1991
Employee suffers burns in butane cloud and falls

On November 3, 1991, Employee #1 was overseeing IST employees who were changing the bundles of drums on the downward flow of light n-hydrocarbons from the Deprop tower to the Reflux drum. For preventive measures, IST employees placed isolation blinds above and below the drum. In addition, the system was shut down, purged with nitrogen, and drained. Once the bundles in the drums were replaced, IST employees began to remove the blinds. Working under fresh air (required by Mobil Oil Refinery), they removed the bottom blind. As they removed the upper blind, vapors, which were being released through the flange and were being suppressed by water, dramatically increased. As Employee #1 stepped forward to tell IST employees to close the flange, he stepped into a cloud of butane gas, approximately 15 feet in diameter. He was immediately overcome, blacked out, and fell to the ground, striking his head on a bleeder valve. An emergency crew arrived on scene and performed first aid. Employee #1 was brought to Little Co. of Mary, in Torrance, CA, and was treated for chemical burns and abrasions of the buttocks, shoulder, and lower extremities.

Keywords: HEAD, UNCONSCIOUSNESS, VAPOR, BUTTOCKS, WORK RULES, CONSTRUCTION, CHEMICAL BURN, FALL, OVEREXPOSURE, ACCIDENTAL DISCHARGE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112088489 Hospitalized injury Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.