Powered by GoogleTranslate

Inspection Detail

Inspection: 112038575 - Mace Corp

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 112038575
Report ID: 0950633
Date Opened: 09/19/1990

Site Address:
Mace Corp
2022 W 11th
Upland, CA 91786

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3823

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/18/1991

Emphasis:

Case Closed: 11/06/1991


Related Activity
Type Activity Nr Safety Health
Accident 361055569
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 7
Current Violations 7 7
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A01 03/18/1991 07/30/1991 $0 $0 $0 P - Petition to Mod Abatement  
2. 01002 Other 3664 A 03/18/1991 04/18/1991 $0 $0 $0 -  
3. 01003 Other 5144 B 03/18/1991 03/18/1991 $0 $0 $0 -  
4. 01004 Other 5194 F01 03/18/1991 04/18/1991 $0 $0 $0 -  
5. 01005 Other 5144 F01 03/18/1991 04/18/1991 $0 $0 $0 -  
6. 01006 Other 5194 G01 03/18/1991 04/18/1991 $0 $0 $0 -  
7. 01007 Other 5194 H02 03/18/1991 04/18/1991 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170193023
Event: 06/19/1990
Employee exposed to Teflon resins

At 11:10 a.m. on June 9, 1990, Employee #1 was performing a Teflon compressing operation when he suddenly became ill with chills, dizziness, and other flu-like symptoms. He immediately drove himself to the urgent care center. Analysis of blood gases and a pulmonary function test were normal, but his carboxyhemoglobin count was elevated. According to the physician, this was because Employee #1 was a chronic smoker. Apparently, he had inhaled Teflon resins while smoking on his break. He was given oxygen and returned to work the next day. The physician recommended that he quit smoking. According to the MSDS sheet, people working with Teflon resins should avoid contamination with any tobacco products because inhalation of the decomposition products of the resin can cause flu-like symptoms, sometimes called polymer fume fever. Employee #1 stated that he frequently became ill when he performed this operation, but this had been the worst episode.

Keywords: INHALATION, CHEMICAL REACTION, DIZZINESS, SMOKING, CHEMICAL VAPOR, TOXIC FUMES, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112038575 Hospitalized injury Other Compressing and compacting machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.