Powered by GoogleTranslate

Inspection Detail

Inspection: 112031125 - Tamco Steel, Inc.

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 112031125
Report ID: 0950633
Date Opened: 11/05/1991

Site Address:
Tamco Steel, Inc.
12459-B Arrow Highway
258849 Cucamonga, CA 91739

Mailing Address:
P.O.Box 325, Rancho Cucamonga, CA 91739

Union Status: Union

SIC:3312

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/13/1992

Emphasis:

Case Closed: 01/23/1992


Related Activity
Type Activity Nr Safety Health
Accident 361339625
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A04 01/13/1992 01/13/1992 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170192447
Event: 10/26/1991
Employee burned by hot slag and molten metal in explosion

At approximately 10:38 p.m. on October 26, 1991, Employee #1 was shoveling excess scrap from around the deck of an electric arc furnace in preparation for the next batch of scrap iron to be melted. As the furnace was being tapped, water infiltrated underneath the molten steel and hydrated it, resulting in an explosion. Employee #1 was struck by hot slag and molten metal, and sustained burns that required hospitalization. It is believed that the water came from worn cooling water panels within the furnace itself. Employee #1's duties did not include operation of the electric arc furnace.

Keywords: BURN, STEEL-MELTING FURN, INADEQUATE MAINT, EXPLOSION, INEXPERIENCE, MOLTEN METAL, STRUCK BY, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112031125 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close