Inspection: 111968376 - Sunsweet Growers Inc

Inspection Information - Office: Redding District Office

 

Inspection Nr: 111968376
Report ID: 0950623
Date Opened: 08/09/1994

Site Address:
Sunsweet Growers Inc
901 N. Walton
Yuba City, CA 95991

Mailing Address:
P. O. Box 232, Yuba City, CA 95992

Union Status: Union

SIC:2034

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/09/1994

Emphasis:

Case Closed: 02/14/1995


Related Activity
Type Activity Nr Safety Health
Accident 362111387
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $6,125 $0 $0 $300 $0 $6,425
Current Penalty $6,125 $0 $0 $300 $0 $6,425
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3308 12/13/1994 08/23/1994 $300 $300 $0 -  
2. 02001 Serious 3300 B 12/13/1994 08/09/1994 $1,125 $1,125 $0 -  
3. 03001 Serious 3300 A 12/13/1994 08/09/1994 $5,000 $5,000 $0 -  

Investigation Summary

Investigation Nr: 170360135
Event: 08/07/1994
Employee burned by hot water and steam

At 9:50 a.m. on August 7, 1994, Employee #1, of Sunsweet Growers, Inc., was working at the prune prep area. He was turning on a steam valve when the valve broke, spraying him with steam. At the same time, an unsecured 4 in. rubber hose, which he had inserted in the top of a 5,000 gal tank, jumped out of the tank and sprayed steam and hot water on his lower body. Employee #1 was able to shut off the valve but not before he received serious first- and second-degree burns to 20 percent of his body including the groin, both thighs, lower abdomen, and upper right arm. Employee #1 required hospitalization. The valve was opened to allow steam to mix with cold water to make hot water to put in the 5,000 gal tank.

Keywords: BURN, UNSECURED, WORK RULES, BOILER, THIGH, EQUIPMENT FAILURE, HOSE, STEAM, VALVE, HOT WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111968376 Hospitalized injury Burn/Scald(Heat) Supervisors; handlers,equip-cleaners,laborers nec
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.