Powered by GoogleTranslate

Inspection Detail

Inspection: 111937306 - Moyer Products

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 111937306
Report ID: 0950625
Date Opened: 11/07/1990

Site Address:
Moyer Products
5741 E. Central
Fresno, CA 93725

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5191

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/07/1990

Emphasis:

Case Closed: 04/25/1991


Related Activity
Type Activity Nr Safety Health
Accident 361274533

Investigation Summary

Investigation Nr: 170202097
Event: 10/04/1990
Employee's eye penetrated by flying metal splinter

At approximately 2:00 p.m. on October 4, 1990, Employee #1, of Moyer Products, Inc., was replacing a bearing on a spreader at the ammonia sulfate bin. He was elevated in a lift cage, hammering the new 3/4 in. shaft and bearing into place when a metal splinter flew off the shaft and penetrated his right eye. Employee #1 was hospitalized for treatment of his injuries. The shafts and bearings were replaced periodically, and Employee #1 had performed this task before.

Keywords: EYE, SPLINTER, MAINTENANCE, PROTECTIVE CLOTHING, PPE, WORK RULES, STRUCK BY, FLYING OBJECT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111937306 Hospitalized injury Foreign Body Ineye Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.