Powered by GoogleTranslate

Inspection Detail

Inspection: 111909784 - East Nicolaus High School

Inspection Information - Office: Redding District Office

 

Inspection Nr: 111909784
Report ID: 0950623
Date Opened: 08/11/1992

Site Address:
East Nicolaus High School
2454 Nicolaus Ave.
Nicolaus, CA 95969

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:8211

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: LocalGovt

Safety/Health: Health

Close Conference: 01/04/1993

Emphasis:

Case Closed: 02/09/1994


Related Activity
Type Activity Nr Safety Health
Accident 361283930
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 7
Current Violations 3 3
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 01/11/1993 01/04/1993 $0 $0 $0 03/08/1993 W - Empr Withdrew  
2. 02001 Serious 5141 A 01/11/1993 01/04/1993 $0 $0 $0 03/08/1993 D - Govt Dismissed Citation has been deleted.
3. 03001 Other 5155 C02 A 01/11/1993 01/04/1993 $0 $0 $0 03/08/1993 W - Empr Withdrew  
4. 04001 Serious 5155 E01 01/11/1993 01/04/1993 $0 $0 $0 03/08/1993 D - Govt Dismissed Citation has been deleted.
5. 05001 Other 5194 E01 01/11/1993 02/16/1993 $0 $0 $0 03/08/1993 W - Empr Withdrew  
6. 06001 Serious 5194 G08 01/11/1993 01/04/1993 $0 $0 $0 03/08/1993 D - Govt Dismissed Citation has been deleted.
7. 07001 Serious 5194 H01 01/11/1993 02/16/1993 $0 $0 $0 03/08/1993 D - Govt Dismissed Citation has been deleted.

Investigation Summary

Investigation Nr: 170697817
Event: 07/27/1992
Employee dies of carbon monoxide poisoning

In the late morning or early afternoon of July 28, 1992, Employee #1 buffed the floor of classroom #208 of East Nicolaus High School with a Honda propane-powered floor buffer. At about 1:00 p.m. or 1:15 p.m., two coworkers of the school system (a custodian and a maintenance and transportation technician) discovered Employee #1 lying on the floor of room #208 toward the middle of the room. The floor buffer was approximately 10 to 12 feet from him by the exit door. The buffer was idling and the room was filled with propane exhaust. According to the two coworkers, they immediately carried Employee #1 outdoors and began CPR. Employee #1 was unresponsive. Within a few minutes, a volunteer from the East Nicolaus Fire Department arrived and continued CPR with a resuscitating tube. Again Employee #1 failed to respond. Within a few minutes, an ambulance arrived and took Employee #1 to Rideout Hospital in Marysville, CA, where he died. The initial autopsy reports showed that Employee #1 had a blood carbon monoxide level of 58 percent.

Keywords: UNCONSCIOUSNESS, ASPHYXIATED, VENTILATION, CPR, WORK RULES, CLEANING, TOXIC ATMOSPHERE, PROPANE, POISONING, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111909784 Fatality Asphyxia Janitors and cleaners
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close