Inspection Detail
Inspection: 111885042 - Dillingham Construction
Inspection Information - Office: American Canyon District Office
Site Address: 
			   Dillingham Construction
			   3485 Pacheco Blvd., Shell Refinery
Martinez, CA 94553
Mailing Address: 
			   5960 Inglewood Drive, Pleasanton, CA 94588
Union Status: Union
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/24/1991
Emphasis:
Case Closed: 01/10/1992
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Accident | 361264971 | 
Investigation Summary
At approximately 1:00 a.m. on February 9, 1991, Employee #1 and a coworker were removing a control valve at a Shell Oil Refinery in Martinez. To keep the valve from falling, the employees used a staging pipe and rope. The coworker held the rope while Employee #1 removed the bolts. When Employee #1 removed the last bolt, the valve swung back and pinched his right ring finger against a flange. Employee #1 was taken to Mt. Diablo Hospital for treatment. Ten days later, the finger was surgically amputated.
Keywords: AMPUTATED, FINGER, CONSTRUCTION, VALVE, REFINERY
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 111885042 | Hospitalized injury | Amputation | Mechanical controls and valve repairers | 
 Translate
Translate