Inspection: 111816161 - Cascade Water Proofing

Inspection Information - Office: Oakland District Office

 

Inspection Nr: 111816161
Report ID: 0950614
Date Opened: 12/24/1992

Site Address:
Cascade Water Proofing
12th Jefferson
Oakland, CA 94612

Mailing Address:
12th Jefferson, Oakland,, CA 94612

Union Status: Union

SIC:1799

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/21/1993

Planning Guide: Health-Construction

Emphasis:

Case Closed: 03/23/1994


Related Activity
Type Activity Nr Safety Health
Accident 361405509
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 6 6
Initial Penalty $1,239 $0 $0 $0 $0 $1,239
Current Penalty $1,239 $0 $0 $0 $0 $1,239
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5144 F01 01/21/1993 02/22/1993 $38 $38 $0 -  
2. 02001 Serious 5144 F02 01/21/1993 02/22/1993 $375 $375 $0 -  
3. 03001 Serious 5144 G 01/21/1993 02/22/1993 $38 $38 $0 -  
4. 04001 Serious 5157 A01 01/21/1993 02/22/1993 $38 $38 $0 -  
5. 06001 Serious 5159 A05 A 01/21/1993 02/22/1993 $375 $375 $0 -  
6. 07001 Serious 5194 E01 B 01/21/1993 02/22/1993 $375 $375 $0 -  

Investigation Summary

Investigation Nr: 170702674
Event: 12/24/1992
Two employees overcome by trichloroethane vapors

Employee #1 was applying Polygard #650LTFR primer to the concrete walls of 5 ft by 5 ft planter boxes with varying depths of 8 ft, 12 ft, and 16 ft. Two of each size (6 in all) were to be primed. They were confined spaces. The primer was pure 1,1,1 trichloroethane (TCE). Employee #1 was wearing a cartridge type half face respirator, rather than the supplied air type required for TCE. Employee #1 was overcome and became unconscious from the toxic TCE vapors. Measurements indicated at least 80,000 ppm of TCE vapors at the bottom of the 16 ft planter box that Employee #1 had entered. The IDLH level is 1,000 ppm. Employee #2, without a respirator, attempted to rescue Employee #1 but was overcome and fell unconscious. The fire department rescued both Employees #1 and #2.

Keywords: TRICHLOROETHANE, UNCONSCIOUSNESS, CONFINED SPACE, IDLH, WORK RULES, CONSTRUCTION, SCBA, TOXIC FUMES, OVEREXPOSURE, RESPIRATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111816161 Non Hospitalized injury Other Occupation not reported
2 111816161 Non Hospitalized injury Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.