Powered by GoogleTranslate

Inspection Detail

Inspection: 111759759 - Huron Agriculture

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 111759759
Report ID: 0950625
Date Opened: 09/16/1991

Site Address:
Huron Agriculture
36610 M Street
Huron, CA 93234

Mailing Address:
P. O. Box 247, Huron, CA 93234

Union Status: NonUnion

SIC:0721

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/18/1991

Emphasis:

Case Closed: 04/01/1992


Related Activity
Type Activity Nr Safety Health
Accident 361276132
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 5 8
Current Violations 2 1 5 8
Initial Penalty $1,300 $0 $0 $0 $0 $1,300
Current Penalty $1,300 $0 $0 $0 $0 $1,300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Repeat 342 A 03/13/1992 09/16/1992 $0 $0 $0 -  
2. 01002 Other 5194 E03 03/13/1992 04/13/1992 $0 $0 $0 -  
3. 01003 Other 5194 G10 03/13/1992 04/13/1992 $0 $0 $0 -  
4. 01004 Other 5194 H01 03/13/1992 04/13/1992 $0 $0 $0 -  
5. 01005 Other 4799 03/13/1992 04/13/1992 $0 $0 $0 -  
6. 01006 Other 4848 A 03/13/1992 04/13/1992 $0 $0 $0 -  
7. 02001 Serious 3203 A 03/13/1992 04/13/1992 $100 $100 $0 -  
8. 03001 Serious 4848 A10 03/13/1992 09/18/1991 $1,200 $1,200 $0 -  

Investigation Summary

Investigation Nr: 170202436
Event: 09/13/1991
Employee burned when leaking gasoline ignites

Employee #1 was using an oxyacetylene torch on the supports of a fuel mix-and-transfer unit. He drained fuel from the auxiliary tank into a 2-gallon plastic bucket. The bucket apparently leaked or was overfilled, and the gasoline flowed to the front of the unit, where Employee #1 had resumed cutting off an additional piece of metal tubing or screening material. A piece of hot slag fell to floor, splattered, and ignited the flow of leaking gasoline. The fire engulfed Employee #1, and he suffered second- and third-degree burns on his arms, legs, and torso.

Keywords: BURN, LEAK, FLAMMABLE LIQUID, AGRICULTURE, WORK RULES, TORSO, GASOLINE, CUTTING AND BURNING, LEG, NON-APPROVED GAS CAN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111759759 Hospitalized injury Burn/Scald(Heat) Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.