Powered by GoogleTranslate

Inspection Detail

Inspection: 111315255 - Municipality Of Metropolitan Seattle

Inspection Information - Office: Dosh Spokane Service Location, Spokane, Wa

 

Inspection Nr: 111315255
Report ID: 1055360
Date Opened: 11/03/1992

Site Address:
Municipality Of Metropolitan Seattle
45th & Interlake (Eastbound)
Seattle, WA 98103

Mailing Address:
11911 E Marginal Way S Bldg A Mssa, Seattle, WA 98168

Union Status: Union

SIC:4111

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: LocalGovt

Safety/Health: Safety

Close Conference: 11/05/1992

Emphasis:

Case Closed: 03/02/1993


Related Activity
Type Activity Nr Safety Health
Accident 361194095
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $750 $0 $0 $0 $0 $750
Current Penalty $750 $0 $0 $0 $0 $750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 0456503902 01/26/1993 11/05/1992 $750 $750 $0 -  

Investigation Summary

Investigation Nr: 170238125
Event: 10/22/1992
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED CONDUCTOR

AN EMPLOYEE WAS WORKING ON A 725-VOLT DC TROLLEY LINE. HE WAS STANDING ON A PLATFORM, WORKING BETWEEN THE POSITIVE AND NEGATIVE CONDUCTORS, WHICH WERE BETWEEN 30 AND 36 INCHES APART. HE HAD REPLACED A HAMICORD AND WAS TIGHTENING A SCHWARTZ COIL WHEN HE CONTACTED THE CONDUCTORS WITH HIS HAND AND THE BACK OF HIS NECK. HE WAS HOSPITALIZED FOR THE ELECTRIC SHOCK HE RECEIVED.

Keywords: E GI IV, ELECTRICAL, ELECTRICIAN, ELECTRICAL WORK, RUNWAY CONDUCTOR, LOCKOUT, ELECTRIC CONDUCTOR, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111315255 Hospitalized injury Electric Shock Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.