Powered by GoogleTranslate

Inspection Detail

Inspection: 111175774 - R.R. Donnelley

Inspection Information - Office: Nv-E-Reno 0953210

 

Inspection Nr: 111175774
Report ID: 0953210
Date Opened: 08/28/1990

Site Address:
R.R. Donnelley
14100 Lear Blvd.
Reno, NV 89506

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2741

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/20/1990

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/20/1990


Related Activity
Type Activity Nr Safety Health
Accident 361024433
Referral 900352105 Yes

Investigation Summary

Investigation Nr: 14238372
Event: 08/26/1990
ELECTRIC SHOCK - CAUSE UNKNOWN

AN EMPLOYEE WAS RE-THREADING THE STRAPPING TAPE IN AN OVAL STRAPPING MACHINE (MODEL NO. JP80MF, SERIAL NO. 800). SHE CONTACTED THE TENSION PLATE WITH HER HAND AND RECEIVED AN ELECTRIC SHOCK. THE DAY AFTER THE ACCIDENT, THE EMPLOYEE ENTERED THE HOSPITAL, COMPLAINING OF A HEADACHE AND RECURRENT NUMBNESS IN HER UPPER RIGHT EXTREMITY. THE NUMBNESS SUBSIDED THAT DAY. THE HEADACHE WAS NOT BELIEVED TO BE A RESULT OF THE ELECTRIC SHOCK. INVESTIGATION DID NOT REVEAL THE CAUSE OF THE ELECTRIC SHOCK.

Keywords: ELECTRICAL, E GI VII, ELECTRIC SHOCK, ELEC EQUIPMENT--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111175774 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.