Inspection Detail
Inspection: 111089173 - Carolina Power And Light Co.
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Carolina Power And Light Co.
Hwy 57
Roxboro, NC 27573
Mailing Address:
P.O. Box 1238, Roxboro, NC 27573
Union Status: NonUnion
SIC:4911
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/15/1993
Emphasis:
Case Closed: 09/20/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360492177 |
Investigation Summary
An employee was performing maintenance work on a boiler at an electric power generation plant. He was assisting a welder in attaching a midrail at the side of a platform. The employee was walking rapidly along the painted surface of a 12-inch-wide steel I-beam. The I-beam was protected on the left side by the boiler and on the right side by a wire rope suspended 41 inches above the I-beam by stanchions. There was no midrail, nor was the employee using any personal fall protection equipment. When he reached the end of the I-beam, he turned 90 degrees to the left to traverse a 12-inch-wide wooden plank spanning a gap between the beam and a working platform. The employee stumbled, fell, and rolled under the wire rope guardrail. He fell 51 feet to a steel catwalk, striking his head on an I-beam on the way down. He died of injuries sustained in the fall.
Keywords: HEAD, SLIP, GUARDRAIL, WALKING SURFACE, ELEC UTILITY WORK, FALL, FALL PROTECTION, WALKING ON BEAM
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111089173 | Occupation Not Listed |