Powered by GoogleTranslate

Inspection Detail

Inspection: 110421245 - Boise Cascade Corp.

Inspection Information - Office: Baton Rouge Area Office

 

Inspection Nr: 110421245
Report ID: 0625700
Date Opened: 02/06/1992

Site Address:
Boise Cascade Corp.
Hwy 165 South
Oakdale, LA 71463

Mailing Address:
P. O. Box 708, Oakdale, LA 71463

Union Status: Union

SIC:2436

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/07/1992

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/16/1992


Related Activity
Type Activity Nr Safety Health
Referral 901260794 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $4,500 $0 $0 $0 $0 $4,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100333 C03 IA 02/26/1992 03/16/1992 $4,500 $4,500 $0 -  

Investigation Summary

Investigation Nr: 556548
Event: 01/10/1992
ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

TWO EMPLOYEES WERE USING A SNORKEL AERIAL LIFT TO REACH A ROOF AREA ABOVE A MILL. THE TWO EMPLOYEES WERE USING A WATER HOSE TO WASH OFF THE METAL ROOF. ONE OF THE EMPLOYEES WAS OPERATING THE CONTROLS IN THE BUCKET OF THE AERIAL LIFT, AND THE OTHER EMPLOYEE WAS USING THE HOSE. AS THEY WERE WASHING THE ROOF, THE OPERATOR MOVED THE BUCKET TO WITHIN 4 TO 5 FEET OF A 13.5-KILOVOLT OVERHEAD POWER LINE THAT WAS LOCATED ABOUT 15 FEET ABOVE THE ROOF. THE BUCKET WAS POSITIONED BETWEEN TWO OF THE CONDUCTORS OF THE OVERHEAD LINE. ELECTRIC CURRENT ARCED TO THE SHOULDER OF THE AERIAL LIFT OPERATOR, WHOSE RIGHT HAND WAS GROUNDED BY CONTACT WITH THE CONTROLS. THE OPERATOR SUSTAINED AN ELECTRIC SHOCK AND SUFFERED SEVERE BURNS TO HIS UPPER BODY. HE WAS HOSPITALIZED IN A BURN UNIT. HIS EMPLOYER HAD A WRITTEN POLICY FOR UNQUALIFIED EMPLOYEES TO MAINTAIN A 10-FOOT MINIMUM CLEARANCE FROM OVERHEAD POWER LINES.

Keywords: BURN, CLOTHING, E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTRIC SHOCK, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 110421245 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.