Powered by GoogleTranslate

Inspection Detail

Inspection: 110317435 - Rohm & Haas

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 110317435
Report ID: 0626700
Date Opened: 05/10/1991

Site Address:
Rohm & Haas
6600 Laporte Freeway, Hr-2 Unit
Deer Park, TX 77536

Mailing Address:
P.O. Box 672, Deer Park, TX 77536

Union Status: Union

SIC:2869

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/03/1991

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 02/27/1992


Related Activity
Type Activity Nr Safety Health
Accident 360969901
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $7,000 $0 $0 $0 $0 $7,000
Current Penalty $7,000 $0 $0 $0 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 A 10/16/1991 10/31/1991 $3,500 $3,500 $0 I - Informal Settlement  
2. 01002 Serious 5A0001 10/16/1991 10/22/1991 $3,500 $3,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14398697
Event: 05/09/1991
Four employees suffer thermal burns from molten sulfur

On May 9, 1991, Employees #1 through #3 were assigned the task of heating a 2 in. carbon pipe, which contained molten sulfur. Approximately 5 ft of the pipe had a cold spot of frozen sulfur. They were instructed to apply heat on the outside of the pipe to melt the sulfur inside, in order to get the system back on line. The employees were using a Rosebud oxygen and acetylene heating torch with open flame. The pipe ruptured, spewing hot liquid sulfur onto their bodies. Employee #4, working for an insulator contractor, was assigned to locate the cold spot and remove pipe insulation. The cold spot was found and the insulation was removed, but the employee remained in the proximity of the budding operation and was also sprayed with hot molten sulfur.

Keywords: SULFUR, PIPE, BURN, ACETYLENE TORCH, CONSTRUCTION, RUPTURE, TORCH

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 110317435 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close