Powered by GoogleTranslate

Inspection Detail

Inspection: 109051698 - Simmons Elevator Co.

Inspection Information - Office: Albany Area Office

 

Inspection Nr: 109051698
Report ID: 0213100
Date Opened: 01/21/1997

Site Address:
Simmons Elevator Co.
500 Federal St.
Troy, NY 12180

Mailing Address:
4903 Jockey St., Ballston Spa, NY 12020

Union Status: NonUnion

SIC:7699

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/24/1997

Emphasis:

Case Closed: 04/08/1997


Related Activity
Type Activity Nr Safety Health
Accident 100740059

Investigation Summary

Investigation Nr: 200740066
Event: 01/20/1997
Employee killed when crushed between elevator car and shaft

At approximately 10:00 a.m. on January 20, 1997, Employee #1, an elevator serviceman, was doing preventative maintenance on a elevator. As he was working on top of the elevator car, he became caught between it and the elevator shaft. Employee #1 sustained traumatic injuries to his chest and head, and was killed. When his body was found by the fire department, neither the emergency STOP nor the inspection buttons had been depressed.

Keywords: CHEST, HEAD, MAINTENANCE, EMERGENCY STOP, CAUGHT BETWEEN, CRUSHED, ELEVATOR, ELEVATOR SHAFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109051698 Fatality Other Supervisors, cleaning and building service workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close