Powered by GoogleTranslate

Inspection Detail

Inspection: 108964198 - Tip Top Roofers

Inspection Information - Office: Atlanta West Area Office

 

Inspection Nr: 108964198
Report ID: 0418200
Date Opened: 04/18/1996

Site Address:
Tip Top Roofers
486 Park Str. Sw
Atlanta, GA 30310

Mailing Address:
2345 Adams Dr. Nw, Atlanta, GA 30318

Union Status: Union

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/03/1996

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 09/11/1996


Related Activity
Type Activity Nr Safety Health
Accident 361119423
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1
Initial Penalty $1,250 $0 $0 $0 $0 $1,250
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260416 G05 08/16/1996 08/22/1996 $0 $1,250 $0 I - Informal Settlement Citation has been deleted.
2. 02001 Other 19260252 A 08/16/1996 08/22/1996 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200200053
Event: 04/16/1996
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU DOWNSPOUT

Five employees were working on the roof of a church. Two of them had removed a loose downspout from the wall of the church and started to bring it up onto the parapet roof. One of these two employees told the other to watch out for a nearby overhead power line and stepped away. As the second employee (Employee #1) continued to pull the downspout, it contacted the power line, and he was electrocuted. The other four employees ran toward the dead employee, but two of them apparently descended from the roof because the downspout was lying on the parapet wall in a horizontal position with its end resting on the power line. The two remaining employees (Employees #2 and #3) were trying to revive their dead coworker. As they were doing this, the downspout shifted and touched a metal pipe that was sticking up out of the roof. This energized the roof, and Employees #2 and #3 received electric shocks. They were hospitalized for their injuries.

Keywords: RAIN SPOUT, OVERHEAD POWER LINE, ROOF, ELECTRICAL, ELECTROCUTED, ROOFER, ELECTRIC SHOCK, E GI IC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 108964198 Fatality Electric Shock Roofers
2 108964198 Hospitalized injury Electric Shock Roofers
3 108964198 Hospitalized injury Electric Shock Roofers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.