Powered by GoogleTranslate

Inspection Detail

Inspection: 108177809 - Vantage Manufacturing Services

Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)

 

Inspection Nr: 108177809
Report ID: 0950411
Date Opened: 09/24/1990

Site Address:
Vantage Manufacturing Services
5213 W Lamar
Glendale, AZ 85301

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3672

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 09/26/1990

Emphasis:

Case Closed: 05/06/1991


Related Activity
Type Activity Nr Safety Health
Accident 360185524
Referral 900137928 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 3 5
Current Violations 1 2 3
Initial Penalty $500 $0 $0 $0 $0 $500
Current Penalty $175 $0 $0 $0 $0 $175
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19101200 G01 11/05/1990 12/05/1990 $250 $250 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Serious 19101200 H 11/05/1990 12/05/1990 $175 $250 $0 I - Informal Settlement  
3. 02001 Other 19100038 A01 11/05/1990 11/29/1990 $0 $0 $0 -  
4. 02002 Other 19101200 E01 11/05/1990 12/05/1990 $0 $0 $0 I - Informal Settlement Citation has been deleted.
5. 02003 Other R4130609 A 11/05/1990 11/08/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170065593
Event: 09/22/1990
Employee burned when isopropanol drum explodes

Employee #1 and coworkers were cleaning up a work area. Employee #1 was trying to determine the amount of isopropanol in a 55 gallon drum and opened the container to look inside. As he was tilting it back and forth, his cigarette lighter fell from his pocket into the drum. Employee #1 stood the drum upright and was bending down to retrieve his lighter when the drum exploded. Employee #1 suffered second-degree burns over approximately 70 percent of his body. The container of isopropanol, a class 1A flammable, was not grounded; the lack of grounding may have caused the vapor to ignite and explode.

Keywords: BURN, FLAMMABLE VAPORS, ISOPROPANOL, WORK RULES, CLEANING, DRUM, EXPLOSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 108177809 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close