Powered by GoogleTranslate

Inspection Detail

Inspection: 107868762 - Dresser-Rand

Inspection Information - Office: Wyoming Department Of Workforce Services - Osha Division

 

Inspection Nr: 107868762
Report ID: 0855610
Date Opened: 10/26/1989

Site Address:
Dresser-Rand
Anschutz Ranch Injection Facility
Evanston, WY 82930

Mailing Address:
100 Chemung St., Painted Post, NY 14870

Union Status: NonUnion

SIC:5084

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 11/03/1989

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 10/08/1991


Related Activity
Type Activity Nr Safety Health
Accident 360608335
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other GN210008 A 11/28/1989 12/15/1989 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 686303
Event: 10/25/1989
1 employee killed, 11 buried in explosion

A new compressor had been added to a system that already used seven compressors. The compressor system is used to compress hydrocarbon gas, a mixture of methane and nitrogen, for re-injection into existing gas and oil production fields in order to enhance production. The oil startup of the new system on an inline Hoerbiger check valve allowed gas to escape. The escaping gas ignited, creating an explosion that blew out the east end of the compressor building. The fire burned Employees #1 through #12. Employee #1 was found dead under a portion of the east end wall that was blown out. It was not determined whether he was outside the building or whether he was blown out with the wall. No ignition source was found.

Keywords: FLAMMABLE VAPORS, EXPLOSION, BURN, NATURAL GAS, EQUIPMENT FAILURE, VALVE, CONSTRUCTION, GAS, NITROGEN, CRUSHED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107868762 Hospitalized injury Burn/Scald(Heat) Construction trades, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.