Powered by GoogleTranslate

Inspection Detail

Inspection: 107730897 - Farmers Elevator Association

Inspection Information - Office: Minnesota Department Of Labor And Industry

 

Inspection Nr: 107730897
Report ID: 0552700
Date Opened: 01/12/1988

Site Address:
Farmers Elevator Association
1200 Arch St.
Hutchinson, MN 55350

Mailing Address:
P.O. Box 158, Hutchinson, MN 55350

Union Status: NonUnion

SIC:5153

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/13/1988

Emphasis:

Case Closed: 03/01/1988


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $400 $0 $0 $400
Current Penalty $0 $0 $400 $0 $0 $400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Repeat 19100022 A 1 02/04/1988 02/07/1988 $400 $400 $0 -  

Investigation Summary

Investigation Nr: 999763
Event: 01/12/1988
Employee injured when grain elevator explodes

On the afternoon of January 11, 1988, Employee #1 was working alone in a concrete grain elevator. Corn was being drawn from the bottom of a concrete storage bin and fed into a 209-foot-tall grain leg by a drag auger manufactured by Schlegal, Inc., North Cambridge, Minnesota. The corn was screened and then run into a load-out bin. Employee #1 later told a coworker that he had stepped outside for a breath of fresh air when he heard the first of three explosions and was then struck on top of the head by falling debris. He staggered into the business office, located approximately 200 feet away from grain elevator, to seek help. Employee #1 sustained multiple lacerations and a skull fracture, for which he was hospitalized. The electric power had gone out, stopping the office clock at 2:44 p.m. The source of ignition is believed to have been the Schlegal drag auger. The drag chain had become jammed at the drive end of the auger where it emptied into the grain legs. Charred grain radiated out from the jammed drag chain.

Keywords: FRACTURE, HEAD, JAMMED, EXPLOSION, LACERATION, SKULL, AUGER, STRUCK BY, GRAIN ELEVATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107730897 Hospitalized injury Fracture Supervisors; handlers,equip-cleaners,laborers nec
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close