Inspection: 107646481 - T C I Corp. Inc.

Inspection Information - Office: Albany

Nr: 107646481Report ID: 0213100Open Date: 03/01/1989

T C I Corp. Inc.
Route 9 H
Ghent, NY 12075
Union Status: NonUnion
SIC: 5093/Scrap and Waste Materials
Mailing: R D 3, Box 153t, Hudson, NY 12534

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Health Close Conference:07/14/1989
Close Case:03/08/1990

Related Activity:TypeIDSafetyHealth
 Accident360365324    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $3,300 $0 $0 $0 $0 $3,300
Current Penalty $2,013 $0 $0 $0 $0 $2,013
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 5A0001 08/10/1989 10/02/1989 $656 $1,000 $0 09/01/1989 F - Formal Settlement
  2. 01002A Serious 19100134 A02 08/10/1989 10/02/1989 $657 $1,000 $0 09/01/1989 F - Formal Settlement
  3. 01002B Serious 19100134 C 08/10/1989 09/15/1989 $0 $0 $0 09/01/1989 F - Formal Settlement
  4. 01003 Serious 19101200 E01 08/10/1989 09/15/1989 $290 $490 $0 09/01/1989 F - Formal Settlement
  5. 01004 Serious 19101200 H02 II 08/10/1989 09/15/1989 $410 $810 $0 09/01/1989 F - Formal Settlement

Accident Investigation Summary
Summary Nr: 14483549Event: 02/28/1989Employee Killed After Inhaling Freon
On February 28, 1989, Employee #1 entered an enclosed vessel 11 ft 6 in. long, 6 ft 4 in. wide, and 10 ft high. The container was open on the top. Employee #1 was cleaning the vessel with trichlorotrifluoroethane, Freon 113. He was in the vessel for approximately 15 minutes then left for approximately 15 to 30 minutes. Upon entering the vessel for a second time, Employee #1 became poisoned and collapsed. He had been in the vessel the second time for less than 5 minutes. The vessel had no mechanical ventilation.
Keywords: lung, confined space, cleaning, inhalation, tank cleaning, freon, poisoning, tank
Inspection Degree Nature Occupation
1 107646481 Fatality Poisoning(Systemic) Helpers, mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.