Inspection Detail
Inspection: 107557316 - Naylor Industrial
Inspection Information - Office: Houston North Area Office
Site Address:
Naylor Industrial
Limestone Station
Jewitt, TX 75846
Mailing Address:
149 Ellsworth, Suite 401, Pasadena, TX 77502
Union Status: NonUnion
SIC:1796
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/14/1991
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 02/13/1992
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360970115 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $750 | $0 | $750 |
Current Penalty | $0 | $0 | $0 | $500 | $0 | $500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19040002 A | 01/06/1992 | 01/09/1992 | $500 | $750 | $0 | I - Informal Settlement |
Investigation Summary
An employee was doing underground repair work on a cooling tower. He fell about 10.7 meters through a 1.8-meter-diameter opening into a circulating water pipe. He died of injuries sustained in the fall.
Keywords: UNGUARDED FL OPENING, WATER PIPE, COOLING TOWER, REPAIR, FALL, FLOOR OPENING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 107557316 | Occupation Not Listed |