Inspection Detail
Inspection: 107557290 - Stewart & Stevenson Services, Inc.
Inspection Information - Office: Houston North Area Office
Site Address: 
			   Stewart & Stevenson Services, Inc.
			   Limestone Station
Jewitt, TX 75846
Mailing Address: 
			   P.O. Box 1647, Houston, TX 77029
Union Status: NonUnion
SIC:1796
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/14/1991
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 03/23/1992
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Accident | 360970115 | 
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total | 
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 | 
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 | 
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 | 
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note | 
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19040002 A | 01/06/1992 | 01/09/1992 | $0 | $0 | $0 | - | 
Investigation Summary
An employee was doing underground repair work on a cooling tower. He fell about 10.7 meters through a 1.8-meter-diameter opening into a circulating water pipe. He died of injuries sustained in the fall.
Keywords: UNGUARDED FL OPENING, WATER PIPE, COOLING TOWER, REPAIR, FALL, FLOOR OPENING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 107557290 | Occupation Not Listed | 
 Translate