Powered by GoogleTranslate

Inspection Detail

Inspection: 107349011 - Occidental Chemical Corporation - Durez Division

Inspection Information - Office: Buffalo Area Office

 

Inspection Nr: 107349011
Report ID: 0213600
Date Opened: 06/28/1993

Site Address:
Occidental Chemical Corporation - Durez Division
5000 Packard Road
Niagara Falls, NY 14304

Mailing Address:
P.O. Box 863, Niagara Falls, NY 14304

Union Status: Union

SIC:2821

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/30/1993

Emphasis:

Case Closed: 01/12/1995


Related Activity
Type Activity Nr Safety Health
Accident 360839195
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 3 2 5
Initial Penalty $13,500 $0 $0 $0 $0 $13,500
Current Penalty $6,000 $0 $0 $0 $0 $6,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100119 F01 I 12/06/1993 12/31/1994 $2,000 $2,125 $0 I - Informal Settlement  
2. 01002 Serious 19100119 H02 II 12/06/1993 12/09/1993 $2,000 $2,125 $0 I - Informal Settlement  
3. 01003 Other 19100120 Q06 IIIA 12/06/1993 01/06/1994 $0 $2,125 $0 I - Informal Settlement  
4. 01004 Serious 19100132 A 12/06/1993 01/06/1994 $2,125 $2,125 $0 I - Informal Settlement Citation has been deleted.
5. 01005 Serious 19100252 A02 VIC 12/06/1993 12/09/1993 $2,000 $5,000 $0 I - Informal Settlement  
6. 02001 Other 19100119 J02 12/06/1993 12/31/1994 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170402093
Event: 06/28/1993
Employees hospitalized after causing explosion with torches

An explosion and fire occurred on the first floor of building M-3B in an area where employees of Holcombe Company were using oxyacetylene torches to remove steel deck flooring. Employees #1 through #6 were injured; all but Employee #3 were hospitalized. It is assumed that the torches ignited combustible gases that collected in the plenum space beneath the steel deck floor.

Keywords: FLAMMABLE VAPORS, WORK RULES, EXPLOSION, ACETYLENE TORCH, FIRE, CUTTING AND BURNING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107349011 Hospitalized injury Burn/Scald(Heat) Mixing and blending machine operators
2 107349011 Hospitalized injury Burn/Scald(Heat) Mixing and blending machine operators
3 107349011 Non Hospitalized injury Bruise/Contus/Abras Mixing and blending machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.