Inspection Detail
Inspection: 107225922 - Gregory Powerline Construction
Inspection Information - Office: Kansas City Area Office
Site Address:
Gregory Powerline Construction
County Rd.#1530.
Edwards, MO 65326
Mailing Address:
8935 N.Farm Rd.,#167, Fair Grove, MO 65648
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/14/1997
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 04/18/1997
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100000207 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $450 | $0 | $0 | $0 | $0 | $450 |
Current Penalty | $450 | $0 | $0 | $0 | $0 | $450 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100137 B02 VIII | 03/14/1997 | 04/09/1997 | $225 | $225 | $0 | - | ||
2. | 01002 | Serious | 19100269 B01 I | 03/14/1997 | 03/20/1997 | $225 | $225 | $0 | - |
Investigation Summary
A power line worker was in an insulated aerial lift, holding onto a grounded guy. The employee was electrocuted when his head contacted a 7200-volt overhead power line.
Keywords: ELEC PROTECT EQUIP, OVERHEAD POWER LINE, ELECTRICAL, POWER LINE WORKER, ELECTROCUTED, E PTD, GUY, ELEC UTILITY WORK, AERIAL LIFT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 107225922 | Fatality | Electric Shock | Electrical power installers and repairers |