Inspection: 107218802 - Keneco, Inc.

Inspection Information - Office: Billings Area Office

 

Inspection Nr: 107218802
Report ID: 0830100
Date Opened: 09/24/1991

Site Address:
Keneco, Inc.
1827 6th St. N.E.
Great Falls, MT 59404

Mailing Address:
625 1st Ave North, Great Falls, MT 59401

Union Status: NonUnion

SIC:7699

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/25/1991

Emphasis:

Case Closed: 04/15/1992


Related Activity
Type Activity Nr Safety Health
Accident 360330518
Referral 901381335 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 1 8
Current Violations 7 1 8
Initial Penalty $4,650 $0 $0 $0 $0 $4,650
Current Penalty $3,000 $0 $0 $0 $0 $3,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 11/07/1991 11/13/1991 $1,500 $1,500 $0 -  
2. 01002 Serious 19100106 B06 11/07/1991 11/09/1991 $750 $1,500 $0 I - Informal Settlement  
3. 01003A Serious 19100333 B02 11/07/1991 12/09/1991 $350 $750 $0 I - Informal Settlement  
4. 01003B Serious 19100333 B02 I 11/07/1991 12/09/1991 $0 $0 $0 -  
5. 01004 Serious 19101200 E01 11/07/1991 12/09/1991 $100 $225 $0 I - Informal Settlement  
6. 01005 Serious 19101200 G08 11/07/1991 12/09/1991 $100 $225 $0 I - Informal Settlement  
7. 01006 Serious 19101200 H 11/07/1991 12/09/1991 $100 $225 $0 I - Informal Settlement  
8. 01007A Serious 19101200 F05 I 11/07/1991 12/09/1991 $100 $225 $0 I - Informal Settlement  
9. 01007B Serious 19101200 F05 II 11/07/1991 12/09/1991 $0 $0 $0 -  
10. 02001 Other 19030002 A01 11/07/1991 11/08/1991 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14432033
Event: 09/12/1991
Employee killed by burns from gasoline fire.

Employee #1 was working on a gasoline pump below ground level in a sump that was approximately 2 feet by 4 feet. The gas leak detector had to be removed to get to the motor capacitor. Gasoline leaked out, releasing fumes that were ignited by a spark from some source. Employee #1 was not wearing a static spark control wrist strap or protective clothing. The electrical power had been de-energized, but not locked out or tagged out. Employee #1 was burned to death.

Keywords: BURN, LEAK, FLAMMABLE VAPORS, PPE, SUMP TANK, FIRE, LOCKOUT, SPARK, GASOLINE, PUMP

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107218802 Fatality Burn/Scald(Heat) Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.