Powered by GoogleTranslate

Inspection Detail

Inspection: 107122046 - National Sun Industries, Inc.

Inspection Information - Office: Bismarck Area Office

 

Inspection Nr: 107122046
Report ID: 0830300
Date Opened: 01/04/1994

Site Address:
National Sun Industries, Inc.
Liberty Road
Enderlin, ND 58027

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2076

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/04/1994

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/22/1995


Related Activity
Type Activity Nr Safety Health
Referral 901382267 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 11 11
Current Violations 11 11
Initial Penalty $16,625 $0 $0 $0 $0 $16,625
Current Penalty $8,313 $0 $0 $0 $0 $8,313
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100119 C01 05/31/1994 06/17/1994 $413 $825 $0 I - Informal Settlement  
2. 01001B Serious 19100119 C02 05/31/1994 06/17/1994 $0 $0 $0 -  
3. 01002A Serious 19100119 D03 I 05/31/1994 06/17/1994 $413 $825 $0 I - Informal Settlement  
4. 01002B Serious 19100119 D03 II 05/31/1994 06/17/1994 $0 $0 $0 -  
5. 01003 Serious 19100119 E01 05/31/1994 12/30/1994 $688 $1,375 $0 I - Informal Settlement  
6. 01004A Serious 19100119 F01 IC 05/31/1994 06/17/1994 $1,750 $3,500 $0 I - Informal Settlement  
7. 01004B Serious 19100119 F01 ID 05/31/1994 06/17/1994 $0 $0 $0 -  
8. 01004C Serious 19100119 F01 IIA 05/31/1994 06/17/1994 $0 $0 $0 -  
9. 01004D Serious 19100119 F01 IIB 05/31/1994 06/17/1994 $0 $0 $0 -  
10. 01004E Serious 19100119 F01 IV 05/31/1994 06/17/1994 $0 $0 $0 -  
11. 01004F Serious 19100119 F03 05/31/1994 06/17/1994 $0 $0 $0 -  
12. 01005A Serious 19100119 G01 I 05/31/1994 06/17/1994 $1,750 $3,500 $0 I - Informal Settlement  
13. 01005B Serious 19100119 G01 II 05/31/1994 06/17/1994 $0 $0 $0 -  
14. 01005C Serious 19100119 G02 05/31/1994 06/17/1994 $0 $0 $0 -  
15. 01005D Serious 19100119 G03 05/31/1994 06/17/1994 $0 $0 $0 -  
16. 01006A Serious 19100119 H02 I 05/31/1994 06/17/1994 $550 $1,100 $0 I - Informal Settlement  
17. 01006B Serious 19100119 H02 III 05/31/1994 06/17/1994 $0 $0 $0 -  
18. 01006C Serious 19100119 H02 V 05/31/1994 06/17/1994 $0 $0 $0 -  
19. 01007A Serious 19100119 I01 05/31/1994 06/17/1994 $550 $1,100 $0 I - Informal Settlement  
20. 01007B Serious 19100119 I02 III 05/31/1994 06/17/1994 $0 $0 $0 -  
21. 01008A Serious 19100119 J02 05/31/1994 09/16/1994 $688 $1,375 $0 I - Informal Settlement  
22. 01008B Serious 19100119 J03 05/31/1994 09/16/1994 $0 $0 $0 I - Informal Settlement  
23. 01008C Serious 19100119 J04 II 05/31/1994 09/16/1994 $0 $0 $0 I - Informal Settlement  
24. 01009A Serious 19100119 L01 05/31/1994 06/17/1994 $688 $1,375 $0 I - Informal Settlement  
25. 01009B Serious 19100119 L04 05/31/1994 06/17/1994 $0 $0 $0 -  
26. 01009C Serious 19100119 L05 05/31/1994 06/17/1994 $0 $0 $0 -  
27. 01010 Serious 19100119 N 05/31/1994 06/17/1994 $413 $825 $0 I - Informal Settlement  
28. 01011 Serious 19101200 F05 I 05/31/1994 09/16/1994 $413 $825 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 879601
Event: 01/04/1994
Employees burned in explosion of flammable vapors

Employees #1 and #2, a leadman and a trainee, were engaged in the normal start-up operation of a sunflower oil extraction process unit. An extractor vessel was circulating and heating liquid hexane solvent. The hexane was flowing in a closed loop while other process equipment was being prepared for normal operations. A downstream vessel known as a desolventizer/toaster had not been purged to eliminate oxygen. It had been heated using high temperature steam, which caused the residual solid product cake to smolder. Hexane vapors released from the extractor vessel had entered the desolventizer/toaster vessel and were ignited by the smoldering residue, resulting in an explosion. Employees #1 and #2, who were standing on a catwalk near the desolventizer/toaster vessel, were struck by a flame ball and hospitalized with burn injuries.

Keywords: BURN, FLAMMABLE VAPORS, WORK RULES, FIRE, EXPLOSION, HEXANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107122046 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 107122046 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.