Powered by GoogleTranslate

Inspection Detail

Inspection: 106339195 - U.S. Geological Survey

Inspection Information - Office: San Francisco Ro

 

Inspection Nr: 106339195
Report ID: 0935000
Date Opened: 12/15/1998

Site Address:
U.S. Geological Survey
345 Middlefield Road, Bldg. 15
Menlo Park, CA 94025

Mailing Address:
345 Middlefield Rd. Mail Stop 225, Menlo Park, CA 94025

Union Status: NonUnion

SIC:9199

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership:  

Safety/Health: Safety

Close Conference: 01/22/1999

Emphasis:

Case Closed: 08/12/1999


Related Activity
Type Activity Nr Safety Health
Accident 361856081
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 5 8
Current Violations 3 5 8
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100219 D01 02/12/1999 02/19/1999 $0 $0 $0 -  
2. 01001B Serious 19100219 E01 I 02/12/1999 02/19/1999 $0 $0 $0 -  
3. 01002 Serious 19100303 H02 I 02/12/1999 03/01/1999 $0 $0 $0 -  
4. 01003 Serious 19100305 G01 III 02/12/1999 03/29/1999 $0 $0 $0 -  
5. 02001 Other 19100303 E 02/12/1999 03/01/1999 $0 $0 $0 -  
6. 02002 Other 19100303 G01 I 02/12/1999 03/29/1999 $0 $0 $0 -  
7. 02003 Other 19100305 G02 III 02/12/1999 03/29/1999 $0 $0 $0 -  
8. 02004 Other 19600025 C 02/12/1999 03/29/1999 $0 $0 $0 -  
9. 02005 Other 19600070 A 02/12/1999 02/18/1999 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 516310
Event: 12/08/1998
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

A 60-year-old employee was working alone in a laboratory. A step up transformer in the laboratory had exposed energized parts. This transformer fed a nearby capacitor. The employee's buttock contacted a part on the capacitor, which was energized at 4242 volts, while his hip was touching a grounded metal chassis. The employee was apparently electrocuted. (His trousers and skin had burn marks.)

Keywords: E GI V, ELECTRICAL, ELECTROCUTED, CAPACITOR, UNGUARDED LIVE PARTS, TESTING LAB

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106339195 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.