Powered by GoogleTranslate

Inspection Detail

Inspection: 106194145 - Garner Communications

Inspection Information - Office: Inactive-Guam 0931310

 

Inspection Nr: 106194145
Report ID: 0931310
Date Opened: 07/19/1993

Site Address:
Garner Communications
Cable Tv Equipment Installation Project
Afame, Sinajana, GU 96926

Mailing Address:
3671 Industry Avenue, Unit B5, Lakewood, CA 90712

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/23/1993

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/01/1994


Related Activity
Type Activity Nr Safety Health
Accident 360400329
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $10,000 $0 $0 $0 $0 $10,000
Current Penalty $10,000 $0 $0 $0 $0 $10,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 11/22/1993 11/26/1993 $2,500 $2,500 $0 -  
2. 01002A Serious 19260301 A 11/22/1993 11/26/1993 $2,500 $2,500 $0 -  
3. 01002B Serious 19260404 F06 11/22/1993 11/26/1993 $0 $0 $0 -  
4. 01003 Serious 19260404 B01 I 11/22/1993 11/26/1993 $2,500 $2,500 $0 -  
5. 01004 Serious 19260950 E01 II 11/22/1993 11/26/1993 $2,500 $2,500 $0 -  

Investigation Summary

Investigation Nr: 14534135
Event: 07/17/1993
ELECTRIC SHOCK - CONTACT WITH ENERGIZED PARTS

A communications worker was in an aerial lift using an electric drill to drill holes in a utility pole. The drill was powered by a truck-mounted generator. The employee was soaking wet from rain. As he turned on the electric drill, he received an electric shock. His coworker on the ground immediately deenergized the generator. Unfortunately, he was too late. The employee in the aerial lift was electrocuted. The power supply cord to the drill was defective, and the conductors inside the cord were exposed.

Keywords: ELEC INSULATION, ELECTRICAL, TELECOM WORK, E TC, ELECTROCUTED, GROUND FAULT, ELECTRIC CORD, ELECTRIC DRILL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106194145 Fatality Electric Shock Misc. electrical & electronic equipment repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.