Powered by GoogleTranslate

Inspection Detail

Inspection: 106109713 - Modern Sign Co. Of Gulf Coast, Inc.

Inspection Information - Office: Mobile Area Office

 

Inspection Nr: 106109713
Report ID: 0418600
Date Opened: 06/04/1991

Site Address:
Modern Sign Co. Of Gulf Coast, Inc.
6353 Cottage Hill Rd.
Mobile, AL 36609

Mailing Address:
5692 Hwy. 90 W., Theodore, AL 36590

Union Status: NonUnion

SIC:3993

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/08/1991

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/27/1991


Related Activity
Type Activity Nr Safety Health
Accident 360960603
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 6
Current Violations 4 2 6
Initial Penalty $2,400 $0 $0 $0 $0 $2,400
Current Penalty $1,000 $0 $0 $0 $0 $1,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 09/11/1991 09/27/1991 $300 $750 $0 I - Informal Settlement  
2. 01002 Serious 19100333 A02 09/11/1991 09/27/1991 $200 $450 $0 I - Informal Settlement  
3. 01003 Serious 19100334 B01 09/11/1991 09/27/1991 $300 $600 $0 I - Informal Settlement  
4. 01004 Serious 19100335 A01 09/11/1991 09/27/1991 $200 $600 $0 I - Informal Settlement  
5. 02001 Other 19040002 A 09/11/1991 10/11/1991 $0 $0 $0 -  
6. 02002 Other 19101200 E01 09/11/1991 10/11/1991 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 604686
Event: 06/03/1991
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED CONDUCTOR

An employee was on a Wilkie metal aerial ladder, installing a 120-volt fluorescent lighting fixture and an electric sign for a shopping center. He had not deenergized the existing circuit before working on it. He grabbed an energized conductor with his left hand and was electrocuted when his right knee touched the metal frame of the sign.

Keywords: E GI IV, ELECTRICAL, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, ADVERTISING SIGN, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106109713 Fatality Electric Shock Misc. electrical & electronic equipment repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close