Powered by GoogleTranslate

Inspection Detail

Inspection: 106104813 - Armstrong Painting Company

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 106104813
Report ID: 0418800
Date Opened: 10/05/1988

Site Address:
Armstrong Painting Company
4920 Nw 79th Ave.
Miami, FL 33166

Mailing Address:
40 Cedar Valley Dr., Kennesaw, GA 30144

Union Status: NonUnion

SIC:1721

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/13/1988

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 06/07/1989


Related Activity
Type Activity Nr Safety Health
Accident 360132740
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations
Initial Penalty $750 $0 $0 $0 $0 $750
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260021 B02 11/28/1988 12/02/1988 $350 $350 $0 12/22/1988 R - Review Commission Citation has been deleted.
2. 01001B Serious 19260416 A03 11/28/1988 12/01/1988 $0 $0 $0 12/22/1988 R - Review Commission Citation has been deleted.
3. 01002A Serious 19260450 A02 11/28/1988 12/02/1988 $400 $400 $0 12/22/1988 R - Review Commission Citation has been deleted.
4. 01002B Serious 19260450 A11 11/28/1988 12/01/1988 $0 $0 $0 12/22/1988 R - Review Commission Citation has been deleted.

Investigation Summary

Investigation Nr: 14354690
Event: 10/05/1988
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LADDER

AN EMPLOYEE WAS PRESSURE CLEANING A BUILDING USING A 32-FOOT-LONG METAL EXTENSION LADDER, WHICH HAD BEEN EXTENDED TO A LENGTH OF ABOUT 27 FEET. A 7620-VOLT OVERHEAD POWER LINE WAS LOCATED ABOUT 10 FEET AWAY FROM THE BUILDING AND 27.5 FEET ABOVE THE GROUND. THE LADDER WAS APPARENTLY BEING MOVED FROM ONE AREA TO ANOTHER. WHILE THE EMPLOYEE WAS MOVING THE LADDER, IT CONTACTED THE OVERHEAD LINE. THE EMPLOYEE WAS ELECTROCUTED.

Keywords: EXTENSION LADDER, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, LADDER, METAL LADDER, E GI IB

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106104813 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close