Powered by GoogleTranslate

Inspection Detail

Inspection: 106050669 - Wollard Airport Equipment Co., Inc.

Inspection Information - Office: Eau Claire Area Office

 

Inspection Nr: 106050669
Report ID: 0523310
Date Opened: 06/18/1996

Site Address:
Wollard Airport Equipment Co., Inc.
Bldg. 15f 800 Wisconsin St.
Eau Claire, WI 54703

Mailing Address:
1125 Starr Ave., Eau Claire, WI 54703

Union Status: NonUnion

SIC:3537

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/19/1996

Emphasis:

Case Closed: 09/09/1996


Related Activity
Type Activity Nr Safety Health
Referral 901928945 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 3 7
Current Violations 3 3 6
Initial Penalty $5,000 $0 $0 $0 $0 $5,000
Current Penalty $2,850 $0 $0 $0 $0 $2,850
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100107 G05 07/12/1996 07/31/1996 $950 $1,250 $0 I - Informal Settlement  
2. 01002A Serious 19100252 A02 VIC 07/12/1996 07/18/1996 $950 $1,250 $0 I - Informal Settlement  
3. 01002B Serious 19100252 A03 II 07/12/1996 07/18/1996 $0 $0 $0 -  
4. 01003A Serious 19100252 A02 XIIID 07/12/1996 08/07/1996 $950 $1,250 $0 I - Informal Settlement  
5. 01003B Serious 19101200 E02 II 07/12/1996 08/07/1996 $0 $0 $0 I - Informal Settlement  
6. 01003C Serious 19101200 H 07/25/1996 08/07/1996 $0 $0 $0 -  
7. 01004 Serious 19101200 H 07/12/1996 08/07/1996 $1,250 $1,250 $0 I - Informal Settlement Citation has been deleted.
8. 02001 Other 19040002 A 07/12/1996 07/31/1996 $0 $0 $0 -  
9. 02002 Other 19100038 A02 07/12/1996 08/07/1996 $0 $0 $0 -  
10. 02003 Other 19100179 J03 07/12/1996 08/07/1996 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14373062
Event: 06/17/1996
Three employees injured in tank explosion

Employee #1 was standing atop a tank that exploded. He struck the ceiling with the tank and rolled off onto the floor. Employee #1 was hospitalized with burns over 40 percent of his body and numerous fractures. Employees #2 and #3 were injured but not hospitalized. The explosion occurred when a welding arc was struck. A spark apparently landed inside a bottom drain that had been cleaned with a solvent less than 24 hours earlier. No purging or ventilation had occurred prior to welding.

Keywords: BURN, FRACTURE, VENTILATION, FLAMMABLE VAPORS, WORK RULES, EXPLOSION, PURGING, SPARK, TANK, ARC WELDING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 106050669 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 106050669 Non Hospitalized injury Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.