Investigation Summary

Investigation Nr: 893594
Event: 08/04/1988
One employee killed, one injured in flash fire

At approximately 8:45 a.m. on August 4, 1988, Employees #1 and #2 were applying bithuthene primer P-3100, an extremely flammable liquid waterproofing material, to a concrete foundation wall. They were working approximately 13 ft from a coworker who was using a propane-powered torch to dry out the concrete prior to application of the primer. A small drainage ditch had been dug along the base of the wall to drain the groundwater away. The primer ran down the wall and into the drainage ditch, where it floated down to the open flame of the torch and ignited. The flames traveled back up to where Employees #1 and #2 were working, igniting the wet primer on the wall. They panicked, and in their haste to escape, kicked over the 5 gallon bucket of primer they had been using. This created a flash condition, engulfing both of them in flames. Employee #1 suffered severe burns on 40 percent of his body and was hospitalized. Employee #2 suffered severe burns over 90 percent of his body and died on August 14, 1988, from burn-related complications. The main cause of this accident was using a highly volatile primer too close to an open flame. There also was no fire extinguisher in the area.

Keywords: FIRE EXTINGUISHER, WORK RULES, BURN, FLAMMABLE LIQUID, FIRE, CONSTRUCTION, PROPANE TORCH

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105705818 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.