Powered by GoogleTranslate

Inspection Detail

Inspection: 105604508 - Geneva Rock Products

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 105604508
Report ID: 0854910
Date Opened: 07/06/1992

Site Address:
Geneva Rock Products
1565 West 400 North
Orem, UT 84057

Mailing Address:
P.O. Box 538, Orem, UT 84059

Union Status: Union

SIC:2951

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/06/1992

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/15/1992


Related Activity
Type Activity Nr Safety Health
Accident 360289409

Investigation Summary

Investigation Nr: 170683791
Event: 07/03/1992
Employee suffers hot oil burns when a flexible line ruptures

Employee #1 was transferring AC 10 mix oil from one underground tank to another in preparation for off-loading more oil from a tank truck. He opened the discharge valve, but the valve was broken internally and in effect remained closed. He then closed the #1 valve to begin the transfer. This resulted in a pressure buildup and rupture of the 6 foot by 6 inch flexible transfer line. Hot oil (325 degrees Fahrenheit) from the ruptured line covered Employee #1, who was standing within 5 feet of the rupture. Employee #1 suffered 3rd-degree burns on his lower arms and 1st- and 2nd-degree burns on his neck and upper arms.

Keywords: BURN, TANK TRUCK, OIL LINE, RUPTURE, NECK, OFF LOADING, ARM

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105604508 Hospitalized injury Burn/Scald(Heat) Miscellaneous plant and system operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.