Powered by GoogleTranslate

Inspection Detail

Inspection: 105491047 - Air Cap Industries

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 105491047
Report ID: 0454510
Date Opened: 03/13/1989

Site Address:
Air Cap Industries
Hwy 261
Manning, SC 29102

Mailing Address:
P. O. Box 430, Manning, SC 29102

Union Status: NonUnion

SIC:3524

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/04/1989

Emphasis:

Case Closed: 04/07/1989


Related Activity
Type Activity Nr Safety Health
Accident 360282776

Investigation Summary

Investigation Nr: 909614
Event: 02/08/1989
Employee's thumb lacerated by press

Employee #1 was freeing a stuck part from an eyelet press, model WT, manufactured by USM Corporation, company #010221, serial #2070, when the bolts under the press that held the air cylinders came loose. The air pressure on the rod holding the dog (which stops the press stroke at 360 degrees) was released and the press descended. Employee #1's thumb was lacerated.

Keywords: WORK RULES, THUMB, EQUIPMENT FAILURE, LOCKOUT, LACERATION, PRESS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105491047 Non Hospitalized injury Cut/Laceration Misc. metal & plastic processing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.