Inspection: 105444822 - Energy Services Group

Inspection Information - Office: South Carolina Priv

Nr: 105444822Report ID: 0454510Open Date: 08/13/1987

Energy Services Group
Route 1 Hwy 290
Duncan, SC 29334
Union Status: NonUnion
SIC: 3599/Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Mailing: 1001 Fannin St Suite 400, Houston, TX 77002

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Health Close Conference:08/26/1987
Planning Guide: Health-Manufacturing Close Case:12/11/1987

Related Activity:TypeIDSafetyHealth
 Accident360775993    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $350 $0 $0 $0 $0 $350
Current Penalty $350 $0 $0 $0 $0 $350
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001A Serious 19100094 D09 V 11/24/1987 12/01/1987 $350 $350 $0 -
  2. 01001B Serious 19100094 D09 VII 11/24/1987 12/31/1987 $0 $0 $0 -
  3. 02001 Other 19100094 D09 V 11/24/1987 12/01/1987 $0 $0 $0 -
  4. 02002 Other 19101200 F04 11/24/1987 11/27/1987 $0 $0 $0 -

Accident Investigation Summary
Summary Nr: 14214969Event: 08/09/1987Employees Exposed To Solvent Vapors From Degreaser
On Sunday, August 9, 1987, Employees #2, #3, and #4 were in the plant while the plant was shut down. They noticed an odor coming from the production area. After investigating, they determined that it was coming from the vapor degreaser in the finishing area. Employee #2 attempted to call the maintenance manager but could not reach him. Employee #3 attempted to shut off the vapor degreaser but was unsuccessful. The vapors set off the fire alarm and the Fire Department responded. Employee #1 donned the Self Contained Breathing Apparatus and chemical protective suit and went into the degreaser and shut it off. Employees #1, #2, #3, and # 4 were taken to the hospital where they showered, were checked as a precaution, and released. The production area doors were opened and the building was ventilated. The degreaser is a 60T degreaser with a capacity of 110-115 gallons, located in an area of approximately 90 feet by 30 feet. The cooling compressor for cold water coils was replaced to avoid the current problem.
Keywords: compressor, protective clothing, vapor, degreaser, shut-off valve
Inspection Degree Nature Occupation
1 105444822 Non Hospitalized injury Other Managers, marketing, advertising, & public rela.
2 105444822 Non Hospitalized injury Other Managers, marketing, advertising, & public rela.
3 105444822 Non Hospitalized injury Dermatitis Secretaries
4 105444822 Non Hospitalized injury Dermatitis Managers and administrators, n.e.c

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.