Powered by GoogleTranslate

Inspection Detail

Inspection: 104704333 - R T Electric Company Inc

Inspection Information - Office: State Of New Mexico Environment Department Occupational Health & Safety Bureau

 

Inspection Nr: 104704333
Report ID: 0653510
Date Opened: 04/28/1988

Site Address:
R T Electric Company Inc
Loretto Towne Center
Las Cruces, NM 88002

Mailing Address:
408 N 17th St, Las Cruces, NM 88005

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/29/1988

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/25/1989


Related Activity
Type Activity Nr Safety Health
Accident 360248256
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 1 1
Initial Penalty $720 $0 $0 $0 $0 $720
Current Penalty $240 $0 $0 $0 $0 $240
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260403 B01 09/06/1988 04/28/1988 $240 $240 $0 09/19/1988 F - Formal Settlement  
2. 01002 Serious 19260403 I02 I 09/06/1988 04/28/1988 $240 $240 $0 09/19/1988 F - Formal Settlement Citation has been deleted.
3. 01003 Serious 19260416 A03 09/06/1988 04/28/1988 $240 $240 $0 09/19/1988 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 14301477
Event: 04/26/1988
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED CONDUCTOR

A plumber was installing water lines at a construction site where a building was undergoing renovation. Some employees of another company were working on two refrigerated air conditioning units located on the roof. The units had been temporarily connected to a 480-volt circuit. When the plumber positioned and ascended his mobile scaffold, he contacted the conductors feeding the air conditioners and was electrocuted. (He was later pronounced dead at an area hospital.)

Keywords: ELEC INSULATION, ELECTRICAL, AIR CONDITIONER, E C, ELECTRIC CONDUCTOR, ELECTROCUTED, UNGUARDED LIVE PARTS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104704333 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close