Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 104642624 - Donrey Outdoor Advertising Company

Inspection Information - Office: Nevada Las Vegas

Nr: 104642624Report ID: 0953220Open Date: 11/01/1988

Donrey Outdoor Advertising Company
1211 West Bonanza Road
Las Vegas, NV 89103
Union Status: NonUnion
SIC: 1799/Special Trade Contractors, Not Elsewhere Classified

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:11/22/1988
Planning Guide: Safety-Construction Close Case:04/24/1989

Related Activity:TypeIDSafetyHealth
 Accident36063048    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 2 2 4
Initial Penalty $1,280 $8,960 $0 $0 $0 $10,240
Current Penalty $1,280 $13,960 $0 $0 $0 $15,240
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Willful 19260105 A 03/31/1989 04/03/1989 $6,980 $4,480 $0 I - Informal Settlement
  2. 01002 Willful 19260550 A15 II 03/31/1989 04/03/1989 $6,980 $4,480 $0 I - Informal Settlement
  3. 02001A Serious 19260020 B02 03/31/1989 04/03/1989 $640 $640 $0 -
  4. 02001B Serious 19260021 B02 03/31/1989 04/03/1989 $0 $0 $0 -
  5. 02001C Serious 19260416 A01 03/31/1989 04/03/1989 $0 $0 $0 -
  6. 02002 Serious 19260416 A03 03/31/1989 04/03/1989 $640 $640 $0 -

Accident Investigation Summary
Summary Nr: 968362Event: 10/28/1988Electric Shock & Fall - Contact With Overhead Line
TWO EMPLOYEES WERE ASSIGNED TO DISMANTLE A 48-FOOT-BY-48-FOOT METAL FRAME BILLBOARD. THE BILLBOARD WAS BEING REMOVED BECAUSE IT WAS TOO CLOSE TO AN OVERHEAD POWER LINE THAT WAS LOCATED ABOUT 4 FEET, 10 INCHES AWAY. THEY WERE USING A MOBILE CRANE TO LIFT THE STEEL PARTS OF THE BILLBOARD. NEITHER EMPLOYEE WAS USING ANY FALL PROTECTION EQUIPMENT WHILE THEY WERE WORKING ON THE BILLBOARD. AS THEY WERE REMOVING AN 18-INCH-WIDE CATWALK, IT CONTACTED A 7200-VOLT-TO-GROUND OVERHEAD POWER LINE . BOTH EMPLOYEES RECEIVED AN ELECTRIC SHOCK AND FELL. ONE OF THEM WAS ELECTROCUTED. HE FELL ABOUT 29 FEET. THE OTHER EMPLOYEE SURVIVED THE ELECTRIC SHOCK AND FELL ABOUT 25 FEET ONTO A METAL ROOF. HE WAS BURNED FROM THE ELECTRIC SHOCK AND RECEIVED MULTIPLE ADDITIONAL INJURIES FROM THE FALL. HE WAS HOSPITALIZED FOR HIS INJURIES.
Keywords: burn, overhead power line, electrical, electrocuted, e c, metal decking, electric shock, fall, fall protection, advertising sign
Inspection Degree Nature Occupation
1 104642624 Fatality Electric Shock Structural metal workers
2 104642624 Hospitalized injury Fracture Structural metal workers
3 104642624 Hospitalized injury Fracture Occupation not reported
4 104642624 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.