Powered by GoogleTranslate

Inspection Detail

Inspection: 104351556 - Jc Van Dyke Construction

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 104351556
Report ID: 0352430
Date Opened: 10/10/1990

Site Address:
Jc Van Dyke Construction
Lot #35 Majors Choice Dr
Bel Air, MD 21001

Mailing Address:
110 Grant St, Aberdeen, MD 21001

Union Status: NonUnion

SIC:1771

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/19/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 02/03/2003


Related Activity
Type Activity Nr Safety Health
Accident 360758288
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 2 5
Current Violations 2 1 2 5
Initial Penalty $970 $5,600 $0 $0 $0 $6,570
Current Penalty $970 $5,600 $0 $0 $0 $6,570
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Willful 19260652 A01 12/13/1990 12/16/1990 $5,600 $5,600 $0 01/17/1991 W - Empr Withdrew  
2. 02001 Serious 19260100 A 12/13/1990 12/16/1990 $410 $410 $0 01/17/1991 W - Empr Withdrew  
3. 03001A Serious 19260651 C02 12/13/1990 12/16/1990 $560 $560 $0 01/17/1991 W - Empr Withdrew  
4. 03001B Serious 19260651 K01 12/13/1990 12/16/1990 $0 $0 $0 01/17/1991 W - Empr Withdrew  
5. 04001 Other 19260020 B01 12/13/1990 01/13/1991 $0 $0 $0 W - Empr Withdrew  
6. 04002 Other 19260021 B02 12/13/1990 01/13/1991 $0 $0 $0 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 878413
Event: 10/09/1990
Employees injured when buried under load of soil

At about 12:30 p.m. on October 9, 1990, Employees #1 and #2, laborers for J.C. Van Dyke Construction Company, were making a drain connection at the bottom of a 7 1/2 ft deep L shaped trench with 90 degree walls at the southeast corner of a house foundation. The south leg of the trench was 32 in. wide by 16 in. long, and the east leg 40 in. wide by 48 ft long. They were bent down and could not be seen by anyone who did not look down into the trench from nearby. There was no ladder in the trench. The loader operator for Robert Preston Excavating Co., Inc., had been told that the drain installation was done, and that he should backfill the trench. Not seeing any activity, he used a #953 Caterpillar track type loader to get a load of soil, which was in heavy, thick clumps. Without sounding his horn, he put the soil at the trench edge and began to push it into the trench. Employees #1 and #2 were caught under the soil and struck by the clumps, sustaining head, neck and back injuries. Employee #2 got free but Employee #1 was partially buried as dirt continued to fall. As Employee #2 tried to get the soil off Employee #1 with his hands, the loader operator saw him and stopped to help rescue Employee #1. Both employees were hospitalized. Backfilling should not have been scheduled until it was certain that the drain installation was complete and that no one was in the trench. There should have been a ladder in the trench for employee egress. The ladder would have signaled activity in the trench.

Keywords: WORK RULES, LADDER, CONSTRUCTION, TRENCH, BURIED, COMMUNICATION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104351556 Hospitalized injury Other Construction laborers
2 104351556 Hospitalized injury Other Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.