Powered by GoogleTranslate

Inspection Detail

Inspection: 104344551 - General Electric Company

Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance

 

Inspection Nr: 104344551
Report ID: 0452110
Date Opened: 10/27/1989

Site Address:
General Electric Company
3301 Old Hartford Road
Owensboro, KY 42301

Mailing Address:
, , 00000

Union Status: Union

SIC:3621

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/22/1989

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 02/02/1990


Related Activity
Type Activity Nr Safety Health
Accident 360209043
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $960 $0 $0 $0 $0 $960
Current Penalty $960 $0 $0 $0 $0 $960
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 338003101 A 01/05/1990 10/27/1989 $320 $320 $0 -  
2. 01002 Serious 19100132 A 01/05/1990 01/11/1990 $320 $320 $0 -  
3. 01003A Serious 19100120 L03 IP 01/05/1990 01/31/1990 $320 $320 $0 -  
4. 01003B Serious 19100120 L03 IF 01/05/1990 01/31/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 780544
Event: 10/27/1989
THIRTY ONE EMPLOYEES ASPHYXIATED BY CHEMICAL FIRE

At 7:50 a.m. on October 27, 1989, a chemical fire occurred at a manufacturing plant injuring thirty-one employees. On October 24, 1989, hazardous waste materials were mixed together prior to being sent to the hazardous waste site. The combined substances were stored outdoors. On October 27, 1989, the 55-gallon drums of material began to heat-up from the oxidizing agent being mixed with non-oxidizing agents. A chemical fire occurred resulting in twenty-nine employees being treated in the emergency room, and two other employees being kept for overnight observation. (Four of the injured employees were not listed on injury lines in the original form.)

Keywords: ASPHYXIATED, FIRE, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104344551 Non Hospitalized injury Asphyxia Management Analysts
2 104344551 Non Hospitalized injury Asphyxia Management Analysts
3 104344551 Non Hospitalized injury Asphyxia Management Analysts
4 104344551 Non Hospitalized injury Asphyxia Inspectors, testers and graders
5 104344551 Hospitalized injury Asphyxia Inspectors, testers and graders
6 104344551 Non Hospitalized injury Asphyxia Occupation not reported
7 104344551 Hospitalized injury Asphyxia Personnel, training & labor relations specialists
8 104344551 Non Hospitalized injury Asphyxia Assemblers
9 104344551 Non Hospitalized injury Asphyxia Cost and rate clerks
10 104344551 Non Hospitalized injury Asphyxia Personnel, training & labor relations specialists
11 104344551 Non Hospitalized injury Asphyxia Rolling machine operators
12 104344551 Non Hospitalized injury Asphyxia Assemblers
13 104344551 Non Hospitalized injury Asphyxia Assemblers
14 104344551 Non Hospitalized injury Asphyxia Assemblers
15 104344551 Non Hospitalized injury Asphyxia Assemblers
16 104344551 Non Hospitalized injury Asphyxia Assemblers
17 104344551 Non Hospitalized injury Asphyxia Assemblers
18 104344551 Non Hospitalized injury Asphyxia Assemblers
19 104344551 Non Hospitalized injury Asphyxia Assemblers
20 104344551 Non Hospitalized injury Asphyxia Helpers, mechanics and repairers
21 104344551 Non Hospitalized injury Asphyxia Occupation not reported
22 104344551 Non Hospitalized injury Asphyxia Assemblers
23 104344551 Non Hospitalized injury Asphyxia Assemblers
24 104344551 Non Hospitalized injury Asphyxia Assemblers
25 104344551 Non Hospitalized injury Asphyxia Assemblers
26 104344551 Non Hospitalized injury Asphyxia Assemblers
27 104344551 Non Hospitalized injury Asphyxia Assemblers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.