Powered by GoogleTranslate

Inspection Detail

Inspection: 103992996 - Continental Machine & Engineering Co Inc

Inspection Information - Office: Indiana Department Of Labor

 

Inspection Nr: 103992996
Report ID: 0551800
Date Opened: 06/15/1988

Site Address:
Continental Machine & Engineering Co Inc
4949 Eugene Huish Dr
East Chicago, IN 46312

Mailing Address:
Po Box 270, East Chicago, IN 46312

Union Status: NonUnion

SIC:3599

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/15/1988

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/05/1989


Related Activity
Type Activity Nr Safety Health
Accident 360469431
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $900 $0 $0 $0 $0 $900
Current Penalty $450 $0 $0 $0 $0 $450
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A03 II 07/29/1988 08/10/1988 $450 $900 $0 08/18/1988 F - Formal Settlement  
2. 02001 Other 19100305 B02 07/29/1988 08/10/1988 $0 $0 $0 08/18/1988 -  

Investigation Summary

Investigation Nr: 732123
Event: 06/14/1988
Employee killed when struck by flying piece of bronze

At approximately 12:10 a.m. on June 14, 1988, Employee #1 was attempting to straighten a 6 in. diameter by 12 ft long mild steel shaft, using a Williams/White 600 ton capacity vertical hydraulic press. The press is located in the northwest corner of the shop. Employee #1 was standing on the south side of the press operating the control handle. To prevent marring, a bronze pad, approximately 1 3/8 in. wide by 1 in. thick by 5 in. long, had been placed between the ram plate and the work piece. A stop block and dial indicator were being used to measure the amount of deflection remaining in the shaft. The work piece had been straightened to within 1/16 in. When the control handle was not released as the ram plate made contact with the stop block, increased pressure was applied to the bronze pad, which flew out of the press in two pieces in a south/north direction. One piece struck Employee #1 in the jaw and lodged in his throat, causing severe carotid artery damage and asphyxiation. Employee #1 was treated and taken to St. Catherine's Hospital in East Chicago, IN, where he died at 1:10 p.m. on June 14, 1988.

Keywords: NECK, STRUCK BY, FLYING OBJECT, HYDRAULIC PRESS, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103992996 Fatality Asphyxia Miscellaneous precision metal workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close