Powered by GoogleTranslate

Inspection Detail

Inspection: 103841102 - M Nakai Repair Service Ltd

Inspection Information - Office: Hi-E-Honolulu

 

Inspection Nr: 103841102
Report ID: 0951510
Date Opened: 03/07/1989

Site Address:
M Nakai Repair Service Ltd
734 N King St
Honolulu, HI 96817

Mailing Address:
288 Mokauea St, Honolulu, HI 96819

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/17/1989

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/20/1989


Related Activity
Type Activity Nr Safety Health
Accident 360106744
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 8 8
Current Violations 8 8
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1120003 04/05/1989 05/08/1989 $0 $0 $0 -  
2. 01002 Other 1130006 A02 04/05/1989 04/10/1989 $0 $0 $0 -  
3. 01003 Other 1210003 C01 04/05/1989 04/12/1989 $0 $0 $0 -  
4. 01004 Other 1220004 B 04/05/1989 04/12/1989 $0 $0 $0 -  
5. 01005 Other 1260002 B02 04/05/1989 04/10/1989 $0 $0 $0 -  
6. 01006 Other 1270006 B01 04/05/1989 05/08/1989 $0 $0 $0 -  
7. 01007 Other 1410002 B11 C 04/05/1989 04/12/1989 $0 $0 $0 -  
8. 01008 Other 1410006 C02 04/05/1989 04/10/1989 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14434294
Event: 03/06/1989
Employee injured when 55 gallon drum explodes during cutting

Employee #1 was cutting a 55 gallon drum when it exploded. He sustained a broken nose and forehead lacerations. Employee #1 indicated that he had not followed the established company procedure to test for combustible gas, and, if the results were positive, to clean and vent a drum before cutting it.

Keywords: HEAD, FLAMMABLE VAPORS, WORK RULES, DRUM, CONSTRUCTION, EXPLOSION, LACERATION, FACE, CUTTING AND BURNING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103841102 Hospitalized injury Fracture Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close