Powered by GoogleTranslate

Inspection Detail

Inspection: 103803797 - City Of Danbury Dpw Public Utilities Division

Inspection Information - Office: Connecticut Department Of Labor, Division Of Occupational Safety & Health

 

Inspection Nr: 103803797
Report ID: 0150900
Date Opened: 07/07/1993

Site Address:
City Of Danbury Dpw Public Utilities Division
155 Deer Hill Avenue
Danbury, CT 06810

Mailing Address:
, , 00000

Union Status: Union

SIC:1611

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: LocalGovt

Safety/Health: Safety

Close Conference: 07/14/1993

Emphasis: N:Trench

Case Closed: 05/04/1994


Related Activity
Type Activity Nr Safety Health
Accident 360737647
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 8 1 9
Current Violations 8 1 9
Initial Penalty $3,920 $0 $0 $0 $0 $3,920
Current Penalty $3,024 $0 $0 $0 $0 $3,024
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C04 II 09/22/1993 11/22/1993 $280 $400 $0 P - Petition to Mod Abatement  
2. 01002 Serious 19260021 B02 09/22/1993 10/18/1993 $392 $560 $0 I - Informal Settlement  
3. 01003 Serious 19260059 E01 09/22/1993 11/22/1993 $280 $400 $0 P - Petition to Mod Abatement  
4. 01004 Serious 19260600 A06 09/22/1993 09/27/1993 $504 $640 $0 I - Informal Settlement  
5. 01005 Serious 19260651 C02 09/22/1993 09/27/1993 $392 $480 $0 I - Informal Settlement  
6. 01006 Serious 19260651 J02 09/22/1993 09/27/1993 $392 $480 $0 I - Informal Settlement  
7. 01007 Serious 19260651 K01 09/22/1993 09/27/1993 $392 $480 $0 I - Informal Settlement  
8. 01008 Serious 19260652 A01 09/22/1993 09/27/1993 $392 $480 $0 I - Informal Settlement  
9. 02001 Other 31037406 C 09/22/1993 09/27/1993 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14216337
Event: 07/07/1993
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Some public works employees were installing a new water main in a trench that was more than 5 feet deep. The boom on a Komatsu PC200LC excavator was being used to lift a bucket on the jobsite. The boom contacted a 7960-volt overhead power line. At the same time, the 7-foot alloy chain sling used to support the bucket touched an employee who was standing on the spoils pile south of the excavation. The sling contacted the right front of the employee's chest. He was electrocuted. Current entrance and exit wounds were found on his feet.

Keywords: BACKHOE BOOM, OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E C, BACKHOE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103803797 Fatality Electric Shock Industrial truck and tractor equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.