Inspection: 103723805 - Phoenix Manufacturing Inc.

Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)

 

Inspection Nr: 103723805
Report ID: 0950411
Date Opened: 10/29/1987

Site Address:
Phoenix Manufacturing Inc.
3655 East Roeser Road
Phoenix, AZ 85036

Mailing Address:
P.O. Box 20663, Phoenix, AZ 85036

Union Status: NonUnion

SIC:3585

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/04/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 02/17/1988


Related Activity
Type Activity Nr Safety Health
Referral 900738154 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100217 E01 I 11/18/1987 11/21/1987 $0 $0 $0 -  
2. 01002 Other 19100217 E01 II 11/18/1987 11/21/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 979005
Event: 12/21/1988
Employee's fingertip amputated by mechanical power press die

At approximately 9:30 a.m. on December 21, 1988, Employee #1, who had been a mechanical power press operator for Phoenix Manufacturing, Inc., for three years, was operating a Benchmaster 5 ton standard mechanical power press, serial #H-7. She was pressing cradle brackets that were approximately 3 in. wide by 6 in. long and installing 90 degree bends on the bracket edge. The tongs could not grip the material so she placed her right hand into the exposed opening of the mechanical power press to remove the flat cradle bracket. The pedal was disengaged. While removing the material, the die double hit, striking Employee #1's right pinkie fingertip and amputating it. This press was not equipped with a guard to prevent the operator from placing any part of her body in the danger zone. It was taken out of service and, at the time of the inspection, remained out of service.

Keywords: DIE, AMPUTATED, POWER PRESS, FINGER, WORK RULES, POINT OF OPERATION, PRESS OPERATOR, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103723805 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.