Inspection: 103550497 - Motorola Communications And Electronics Inc.

Inspection Information - Office: Milwaukee

Nr: 103550497Report ID: 0523400Open Date: 11/04/1988

Motorola Communications And Electronics Inc.
3600 52nd Street
Kenosha, WI 53140
Union Status: NonUnion
SIC: 7622/Radio and Television Repair Shops
Mailing: 11408 W. Lincoln Ave., West Allis, WI 53227

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:12/12/1988
Planning Guide: Safety-Manufacturing Close Case:05/18/1989

Related Activity:TypeIDSafetyHealth
 Accident360116560    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 7 7
Current Violations 3 4 7
Initial Penalty $3,960 $0 $0 $0 $0 $3,960
Current Penalty $3,000 $0 $0 $0 $0 $3,000
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19260408 C04 12/19/1988 12/22/1988 $1,000 $1,000 $0 -
  2. 01002 Serious 19260416 A01 12/19/1988 12/22/1988 $1,000 $1,000 $0 -
  3. 01003 Serious 19260416 A03 12/19/1988 12/22/1988 $1,000 $1,000 $0 -
  4. 01004 Other 19101200 E01 12/19/1988 04/23/1989 $0 $240 $0 I - Informal Settlement
  5. 01005 Other 19101200 F04 I 12/19/1988 04/23/1989 $0 $240 $0 I - Informal Settlement
  6. 01006 Other 19101200 G01 12/19/1988 04/23/1989 $0 $240 $0 I - Informal Settlement
  7. 01007 Other 19101200 H 12/19/1988 04/23/1989 $0 $240 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 14500094Event: 11/03/1988Electric Shock - Contact With Power Line Thru Antenna
AN EMPLOYEE WAS WORKING ALONE, REMOVING A 20-FOOT-LONG RADIO ANTENNA FROM A WALL-MOUNTED BRACKET ON A ROOF TOP. AFTER HE REMOVED THE EXISTING ANTENNA, HE WAS GOING TO REPLACE IT WITH A NEW ONE. AS THE EMPLOYEE LIFTED THE OLD ANTENNA OUT OF THE BRACKET, IT CONTACTED A 28.5-KILOVOLT OVERHEAD POWER LINE, AND HE WAS ELECTROCUTED.
Keywords: overhead power line, roof, electrical, electrocuted, antenna, e gi ic
Inspection Degree Nature Occupation
1 103550497 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close