Powered by GoogleTranslate

Inspection Detail

Inspection: 103421368 - Nova Group, Inc.

Inspection Information - Office: Boston North Area Office

 

Inspection Nr: 103421368
Report ID: 0134000
Date Opened: 10/02/1989

Site Address:
Nova Group, Inc.
Grenier Street
Hanscom Afb, MA 01731

Mailing Address:
P.O. Box 4050, Napa, CA 94558

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/10/1989

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 01/23/1990


Related Activity
Type Activity Nr Safety Health
Referral 901442939 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 2 7
Current Violations 4 1 2 7
Initial Penalty $2,900 $19,000 $0 $0 $0 $21,900
Current Penalty $2,600 $5,000 $0 $0 $0 $7,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260550 A02 11/15/1989 11/16/1989 $100 $900 $0 I - Informal Settlement  
2. 01002 Serious 19260550 A12 11/15/1989 11/16/1989 $500 $1,000 $0 I - Informal Settlement  
3. 01003 Serious 19260550 A15 I 11/15/1989 11/16/1989 $1,000 $1,000 $0 I - Informal Settlement  
4. 02001 Willful 19260020 A04 11/15/1989 11/16/1989 $5,000 $10,000 $0 I - Informal Settlement  
5. 02002 Serious 19260021 B02 11/15/1989 11/16/1989 $1,000 $9,000 $0 I - Informal Settlement  
6. 03001 Other 19260350 A09 11/15/1989 11/16/1989 $0 $0 $0 I - Informal Settlement  
7. 03002 Other 19260350 J 11/15/1989 11/16/1989 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 660548
Event: 09/28/1989
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

TWO EMPLOYEES, A LABORER AND A WELDER, WERE POSITIONING A STEAM PIPE THAT WAS BEING LIFTED BY A GROVE RT60S TRUCK CRANE INTO A CONCRETE CULVERT. AFTER THE PIPE HAD BEEN ALIGNED, THE WELDER TACK WELDED ONE END OF THE PIPE WHILE THE LABORER BEGAN REMOVING THE NYLON CHOKER FROM THE WIRE ROPE SLING HOLDING THE PIPE. AS TENSION WAS REMOVED, THE BOOM OF THE CRANE CONTACTED AN OVERHEAD POWER LINE. THE LABORER SUSTAINED SERIOUS BURNS TO HIS RIGHT ARM, FACE, CHEST, BOTH LEGS, AND BOTH FEET.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, E C, ELECTRIC SHOCK, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103421368 Hospitalized injury Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.