Powered by GoogleTranslate

Inspection Detail

Inspection: 103379335 - Dayton Power And Light Company

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 103379335
Report ID: 0522000
Date Opened: 06/17/1994

Site Address:
Dayton Power And Light Company
Us Rt 52(Killen Station)
Manchester, OH 45144

Mailing Address:
Us Rt 52 Killen Station, Manchester, OH 45144

Union Status: Union

SIC:4911

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/04/1994

Emphasis:

Case Closed: 01/14/1997


Related Activity
Type Activity Nr Safety Health
Accident 360169924
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $14,000 $0 $0 $0 $0 $14,000
Current Penalty $0 $0 $0 $0 $12,000 $12,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Unclass 19100038 A01 08/24/1994 09/20/1994 $6,000 $7,000 $0 09/16/1994 F - Formal Settlement  
2. 01002 Unclass 19100038 A05 III 08/24/1994 09/20/1994 $6,000 $7,000 $0 09/16/1994 F - Formal Settlement  

Investigation Summary

Investigation Nr: 700294
Event: 06/16/1994
EMPLOYEE DIED OF HYPERTHERMIA DURING RESCUE OPERATION

A trained emergency medical technician for an electric utility was participating in a rescue operation inside a 900-foot-tall chimney. The stack elevator had malfunctioned. Outside the chimney stack, the temperature was 15 degrees. Inside the stack, the temperature was about 150 degrees. Two rescue teams were performing the rescue, and they had difficulty because of the extreme heat. The medical technician was at the 450-foot level landing. He started having trouble breathing and lost consciousness. He died of hyperthermia.

Keywords: HEAT, HEAT STROKE, ELEC UTILITY WORK, CHIMNEY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103379335 Fatality Heat Exhaustion Not specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.