Powered by GoogleTranslate

Inspection Detail

Inspection: 103378907 - Mid-Ohio Industrial Cleaning

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 103378907
Report ID: 0522000
Date Opened: 06/01/1994

Site Address:
Mid-Ohio Industrial Cleaning
1801 Crawford St., Door 350
Middletown, OH 45043

Mailing Address:
P.O. Box 138, Excello Branch, Middletown, OH 45044

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/29/1994

Emphasis:

Case Closed: 05/17/1995


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $6,000 $0 $0 $0 $0 $6,000
Current Penalty $6,000 $0 $0 $0 $0 $6,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100146 C04 08/29/1994 09/15/1994 $2,500 $2,500 $0 -  
2. 01002 Serious 19100147 C04 II 08/29/1994 09/15/1994 $2,500 $2,500 $0 -  
3. 01003 Serious 19100147 D04 I 08/29/1994 09/01/1994 $1,000 $1,000 $0 -  

Investigation Summary

Investigation Nr: 837690
Event: 04/20/1994
Employees killed by flash fire/explosion in confined space

At approximately 10:15 a.m. on April 20, 1994, Employees #1, #3, and #4 had entered the #1 ammonia scrubber (a confined space) to reinstall serviced piping pieces. Employee #2 was acting as attendant. Flammable gas leaked undetected into the vessel and was ignited by any of several possible ignition sources. When the gas flashed, the pressure created by the rapid fire impacted on Employee #2, killing him. Employees #1, #3, and #4 received internal burns. In addition, the pressure front dislodged the trays upon which they were standing, causing Employees #1 and #3 to fall approximately 50 ft to the bottom of the vessel and Employee #4 to be thrown onto and suspended by some of the piping already installed. Employees #1, #3, and #4 were also killed.

Keywords: LEAK, FLAMMABLE VAPORS, EXPLOSION, PIPE, BURN, FIRE, WORK RULES, INSTALLING, CONFINED SPACE, CONSTRUCTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103378907 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.