Powered by GoogleTranslate

Inspection Detail

Inspection: 103340840 - Ferrellgas

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 103340840
Report ID: 0522500
Date Opened: 07/09/1996

Site Address:
Ferrellgas
4401 Broadway
Grove City, OH 43123

Mailing Address:
6488 East Main Street, Reynoldsburg, OH 43068

Union Status: NonUnion

SIC:5984

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/30/1996

Emphasis:

Case Closed: 06/17/1997


Related Activity
Type Activity Nr Safety Health
Accident 360327092
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 7
Current Violations 4 4
Initial Penalty $42,000 $0 $0 $0 $0 $42,000
Current Penalty $20,500 $0 $0 $0 $0 $20,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100110 B13 IIB2 09/13/1996 10/09/1996 $7,000 $7,000 $0 10/07/1996 F - Formal Settlement Citation has been deleted.
2. 01002 Serious 19100110 B17 II 09/13/1996 10/02/1996 $7,000 $7,000 $0 10/07/1996 F - Formal Settlement Citation has been deleted.
3. 01003 Serious 19100110 B19 III 09/13/1996 10/02/1996 $7,000 $7,000 $0 10/07/1996 F - Formal Settlement  
4. 01004 Serious 19100132 A 09/13/1996 10/09/1996 $7,000 $7,000 $0 10/07/1996 F - Formal Settlement Citation has been deleted.
5. 01005 Serious 19100132 D01 09/13/1996 10/02/1996 $6,500 $3,500 $0 10/07/1996 F - Formal Settlement  
6. 01006 Serious 19100136 A 09/13/1996 10/09/1996 $0 $3,500 $0 10/07/1996 F - Formal Settlement  
7. 01007 Serious 19101200 H01 09/13/1996 10/09/1996 $7,000 $7,000 $0 10/07/1996 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200753069
Event: 07/08/1996
burn - lp gas explosion caused by static electricity

Three employees were working in a building, bleeding off liquid petroleum gas cylinders. The building ventilation was inadequate to dissipate the gas vapors, and the flammable gas filled the building. (The relative humidity was at 32 percent, and winds were calm.) An undetermined source of static electricity ignited the gas vapors and caused an explosion, which leveled the facility. The three employees suffered second- and third-degree burns. One of them broke his leg. The employees were hospitalized for their injuries.

Keywords: BURN, STATIC ELECTRICITY, E GI III, ELECTRICAL, VENTILATION, FLAMMABLE VAPORS, EXPLOSION, LP GAS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103340840 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 103340840 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 103340840 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close