Powered by GoogleTranslate

Inspection Detail

Inspection: 103275327 - Quality Tower Service, Inc.

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 103275327
Report ID: 0522000
Date Opened: 06/10/1993

Site Address:
Quality Tower Service, Inc.
6649 Hearne Rd.
Cincinnati, OH 45248

Mailing Address:
P.O. Box 970 - 35 Grace Drive, Powell, OH 43065

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/14/1993

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 06/18/1998


Related Activity
Type Activity Nr Safety Health
Accident 360119705
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 8 2 10
Current Violations 8 1 1 10
Initial Penalty $27,500 $70,000 $0 $0 $0 $97,500
Current Penalty $7,000 $12,000 $0 $0 $5,000 $24,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B01 11/30/1993 12/14/1993 $1,250 $5,000 $0 12/07/1993 F - Formal Settlement  
2. 01002 Serious 19260020 B02 11/30/1993 12/14/1993 $1,250 $5,000 $0 12/07/1993 F - Formal Settlement  
3. 01003 Serious 19260021 B02 11/30/1993 12/14/1993 $1,250 $5,000 $0 12/07/1993 F - Formal Settlement  
4. 01004 Serious 19260404 B01 I 11/30/1993 12/06/1993 $650 $2,500 $0 12/07/1993 F - Formal Settlement  
5. 01005 Serious 19260550 A01 11/30/1993 12/14/1993 $650 $2,500 $0 12/07/1993 F - Formal Settlement  
6. 01006 Serious 19260550 A02 11/30/1993 12/14/1993 $650 $2,500 $0 12/07/1993 F - Formal Settlement  
7. 01007 Serious 19260550 A05 11/30/1993 12/14/1993 $650 $2,500 $0 12/07/1993 F - Formal Settlement  
8. 01008 Serious 19260550 A06 11/30/1993 12/14/1993 $650 $2,500 $0 12/07/1993 F - Formal Settlement  
9. 02001A Unclass 19260251 A01 11/30/1993 12/03/1993 $5,000 $35,000 $0 12/07/1993 F - Formal Settlement  
10. 02001B Unclass 19260251 A02 11/30/1993 12/03/1993 $0 $0 $0 12/07/1993 F - Formal Settlement  
11. 02001C Unclass 19260251 A04 11/30/1993 12/03/1993 $0 $0 $0 12/07/1993 F - Formal Settlement  
12. 02001D Unclass 19260251 E01 11/30/1993 12/03/1993 $0 $0 $0 12/07/1993 F - Formal Settlement  
13. 02002 Willful 19260552 B01 II 11/30/1993 12/03/1993 $12,000 $35,000 $0 12/07/1993 F - Formal Settlement  

Investigation Summary

Investigation Nr: 14371298
Event: 06/10/1993
Employee killed, one injured in fall from gin pole derrick

Employees #1 and #2 were rigging and preparing to lift a 65 ft long gin pole type derrick in order to dismantle a 200 ft cable television communications tower. The gin pole was being raised to the top of the tower by means of wire rope hoisting equipment, winch and block. The top block was rigged and secured to the tower at a point 4 ft below the top, by means of an unmarked synthetic web chocker. The gin pole was secured to the winch line and then Employees #1 and #2 tied off to the pole in order to ride the load up to the work location. Employee #1 was tied off approximately 40 ft up on the pole, and Employee #2 was tied off at the bottom. When the gin pole was raised approximately 25 ft up the tower, the chocker securing the top block failed and the gin pole (load) fell to the ground. Employee #1 was thrown out of his safety belt due to the shock and fell to the ground. He was killed instantly. Employee #2 rode the load to the ground and suffered multiple fractures.

Keywords: DERRICK, GIN POLE, FRACTURE, COMMUNICATION TOWER, DISMANTLING, HOISTING MECHANISM, SAFETY BELT, CONSTRUCTION, EQUIPMENT FAILURE, FALL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103275327 Fatality Fracture Occupation not reported
2 103275327 Hospitalized injury Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close