Powered by GoogleTranslate

Inspection Detail

Inspection: 102970852 - American Cyanamid Company

Inspection Information - Office: Charleston Area Office

 

Inspection Nr: 102970852
Report ID: 0316400
Date Opened: 05/13/1988

Site Address:
American Cyanamid Company
Rt. 2
Willow Island, WV 26190

Mailing Address:
, , 00000

Union Status: Union

SIC:2879

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 06/10/1988

Emphasis:

Case Closed: 02/22/1989


Related Activity
Type Activity Nr Safety Health
Accident 360659320
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $1,000 $0 $0 $0 $0 $1,000
Current Penalty $1,000 $0 $0 $0 $0 $1,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 06/22/1988 12/22/1988 $1,000 $1,000 $0 -  

Investigation Summary

Investigation Nr: 14231955
Event: 05/13/1988
Employee killed, another injured during tank explosion

Employee #1, a chemist, Employee #2, and two coworkers were assigned to unplug a feed line to a chemical reactor that was used to form thio-bis as an intermediate product. The plug had occurred on the night shift; the day shift crew began the cleanout operation by flushing the line with toluene after nitrogen pressure failed to free the line. The toluene cleared the line, but the sulfur dichloride still would not feed, so the employees added toluene to the feed tank that was used to feed sulfur dichloride into the reactor. After the first of two 55 gallon drums was added through an air pump Employee #1 went to the tank to feel if it were heating, which would have shown a reaction inside. The blow-out disk released and within one or two seconds the tank exploded, killing Employee #1. Employee #2 was injured by debris and fire. The tank had contained approximately 900 lb of sulfur dichloride and approximately 35 gallons of toluene.

Keywords: WORK RULES, CLEANING, FIRE, TOLUENE, EXPLOSION, CHEMICAL REACTION, FLYING OBJECT, TANK, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102970852 Fatality Concussion Chemists, except biochemists
2 102970852 Hospitalized injury Burn(Chemical) Chemical technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close